Skip to product information
Descrizione
Garanzie e Resi
Recensioni

The 6000S device is a portable ventilator designed to provide reliable emergency ventilation, with preconfigured optimized settings for adults, children, and infants, and a quick-start feature that makes it ready for use anywhere and at any time.
It provides the necessary ventilation options with a color-coded system and arrows that simplify quick and safe parameter settings for each patient group (adults, children, and infants of at least 10 kg).
Intelligent guidelines in CPR mode.
Long battery operating life.
The lightweight and compact ventilator, weighing only 1.3 kg, is easily portable with one hand.
Suitable for use in various rescue situations, during patient movement, and during transport in ambulances and hospitals.
Rescue, vehicle transport, long-distance transport, hospital transport.

Main features:
- Portable and easy operation
- Innovative voice guidance
- Tidal volume range: 100 - 1500 ml
- Air Mix option for 60% oxygen
- 3 knobs for flexible parameter adjustment
- On-screen display of airway pressure and ventilation mode
- 3 ventilation modes: IPPV, assist control, and manual control
- Rechargeable lithium-ion battery with over 10 hours of operation

Technical specifications:
Display category: Class IIB
Degree of protection against electric shock: BF
Degree of protection against liquid ingress: IPX4
Degree of protection against explosion hazard: ordinary equipment, without explosion protection; do not use with flammable anesthetics
Mode of operation: continuous running equipment
Dimensions: 240 x 120 x 100 mm including connectors
Weight: approximately 1.3 kg
Display: 2.4” TFT
Display color resolution ratio: 320*240
Pressurized gas connection: external thread 9/16- 18
Ventilation tube connection: Outside diameter 15 mm
Inside diameter 20 mm

Operation:
Temperature range: - 20 °C to + 50°C
Humidity: 15% to 95%
Air pressure: 70kPa to 110 kPa

Storage and transport:
Temperature range: -20°C to +50°C
Humidity: ≤95%
Air pressure: 70kPa to 110 kPa
Power supply: AC: 100 to 240 V; 1.5 to 4A; 50/60 Hz
DC: 12 V Adapter
Battery: standard lithium 7.4V; 3400 mAh.
Duration: more than 10 hours
Operating temperature: -20°C to +50°C
Ventilation modes: IPPV; A/C; CPR
Operating pressure: 2.7 to 6.0 bar

Required gas supply:
Standard GAS:
- Supply pressure at least 2.7 bar
- Flow at least 70 l/min oxygen (ATPD)

Optimal GAS supply:
- Supply pressure: at least 4.5 bar
- Flow less than 80 l/min oxygen (ATPD)

Inspiration-expiration ratio: constant 1:1.67
Minute volume (MV): continuously variable from 3 to 20 l/min (ATPD)
Ventilation frequency: continuously variable from 5 to 40 min⁻¹
Oxygen concentration: No air mix 100%
Minute volume tolerance: ±20%
Max ventilation pressure: 20 to 60 mbar
Airway pressure safety: ≤ 74 mbar
Manometer accuracy: 0 to 60 mbar Deviation ±5%
Trigger sensitivity: -2MBAR standard deviation ± 5%
Ventilation tube: 20 to 60 mb

Patient valve resistance:
- Inspiration <6 mbar at 30, 60 l/min
- Expiration <6 mbar at 30, 60 l/min
- Emergency air intake <6 mbar at 15, 30 l/min
Respiratory compliance: 100 ml/cmH2O
Voice alarm silence time ≤120s
Language: supports up to 5 languages

Regulations: EN794, ISO9001, ISO13485, EN1789

Storage:
Keep the device in a dry place and do not expose it to direct sunlight
Observe the temperatures recommended by the device manufacturer
Refer to the user manual for further information

Maintenance and cleaning:
Refer to the instruction manual for further information
Clean the instrument with a cloth slightly dampened with a simple disinfectant
Attention: Do not immerse the device in water or liquids

Included items:
1 6000S pulmonary ventilator
1 Reusable breathing circuit
1 Breathing valve
1 Ventilation tube (EU standard)
1 Large hook for silicone mask
1 Reusable silicone adult mask Size 5
1 Silicone head harness (for adult)
1 PEEP valve
1 Power adapter (EU standard)
1 AC power cord (EU standard)
1 User Manual

Codice CFS: SE15562

Marca: Amoul

Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.

LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).

In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.

In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.

Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:

  • Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
  • Di uguale qualità rispetto ad un campione o modello analogo
  • Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
  • Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore

Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.

Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.

Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:

  • non comprendenti imballi, accessori e manualistiche originali.
  • ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
  • la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.

Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.

Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.

Sede Centrale (indirizzo geografico presentazione reclami):

CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608

P.IVA: 01883060491 - CCIAA e REA: 205156

Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30

→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica

In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.


Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.

Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.

Termine per l'esercizio del diritto di recesso

Il periodo di recesso scade dopo 14 giorni:

  • dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
  • nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.

Modalità di esercizio del diritto di recesso

Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.

La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.

Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.

Restituzione dei prodotti

Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.

Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.

La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.

Stato dei prodotti restituiti

Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.

Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.

La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.

Rimborso

In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.

Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.

CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.

Esclusioni dal diritto di recesso

Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:

  • ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
  • ai beni confezionati su misura o chiaramente personalizzati;
  • agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.

Foro competente

Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.

Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta

Codice prodotto: SE15562

Electronic lung ventilator 6000S

- Ventilation modes: IPPV, A/C, CPR
- Display: 2.4" TFT color display
- Unit weight: 1.3kg
- Air MIX function
- Operates simultaneously with the Amoul® CPR device via Bluetooth module
- Color coding simplifies quick parameter settings for each patient group
- Visible and audible alarm
- IP44 protection class, CE2797 certified, EN1789 certified

Regular price €1.672,50

(IVA esclusa)

Sale price €1.672,50

(IVA esclusa)

€2040,45 (IVA 22% inclusa)

Shipping calculated at checkout.

Acquistabile in renting se titolari di p.iva da almeno due anni: Rate a partire da 36,15€ con

Paga fino a 12 rate senza costi con

Ordinabile - Spedizione in 7 giorni

Spedizione gratuita
Recommend

Shipping in 24/48h for in-stock products

Technical support Spare parts, calibration services, etc...

Descrizione
Garanzie e Resi
Recensioni

The 6000S device is a portable ventilator designed to provide reliable emergency ventilation, with preconfigured optimized settings for adults, children, and infants, and a quick-start feature that makes it ready for use anywhere and at any time.
It provides the necessary ventilation options with a color-coded system and arrows that simplify quick and safe parameter settings for each patient group (adults, children, and infants of at least 10 kg).
Intelligent guidelines in CPR mode.
Long battery operating life.
The lightweight and compact ventilator, weighing only 1.3 kg, is easily portable with one hand.
Suitable for use in various rescue situations, during patient movement, and during transport in ambulances and hospitals.
Rescue, vehicle transport, long-distance transport, hospital transport.

Main features:
- Portable and easy operation
- Innovative voice guidance
- Tidal volume range: 100 - 1500 ml
- Air Mix option for 60% oxygen
- 3 knobs for flexible parameter adjustment
- On-screen display of airway pressure and ventilation mode
- 3 ventilation modes: IPPV, assist control, and manual control
- Rechargeable lithium-ion battery with over 10 hours of operation

Technical specifications:
Display category: Class IIB
Degree of protection against electric shock: BF
Degree of protection against liquid ingress: IPX4
Degree of protection against explosion hazard: ordinary equipment, without explosion protection; do not use with flammable anesthetics
Mode of operation: continuous running equipment
Dimensions: 240 x 120 x 100 mm including connectors
Weight: approximately 1.3 kg
Display: 2.4” TFT
Display color resolution ratio: 320*240
Pressurized gas connection: external thread 9/16- 18
Ventilation tube connection: Outside diameter 15 mm
Inside diameter 20 mm

Operation:
Temperature range: - 20 °C to + 50°C
Humidity: 15% to 95%
Air pressure: 70kPa to 110 kPa

Storage and transport:
Temperature range: -20°C to +50°C
Humidity: ≤95%
Air pressure: 70kPa to 110 kPa
Power supply: AC: 100 to 240 V; 1.5 to 4A; 50/60 Hz
DC: 12 V Adapter
Battery: standard lithium 7.4V; 3400 mAh.
Duration: more than 10 hours
Operating temperature: -20°C to +50°C
Ventilation modes: IPPV; A/C; CPR
Operating pressure: 2.7 to 6.0 bar

Required gas supply:
Standard GAS:
- Supply pressure at least 2.7 bar
- Flow at least 70 l/min oxygen (ATPD)

Optimal GAS supply:
- Supply pressure: at least 4.5 bar
- Flow less than 80 l/min oxygen (ATPD)

Inspiration-expiration ratio: constant 1:1.67
Minute volume (MV): continuously variable from 3 to 20 l/min (ATPD)
Ventilation frequency: continuously variable from 5 to 40 min⁻¹
Oxygen concentration: No air mix 100%
Minute volume tolerance: ±20%
Max ventilation pressure: 20 to 60 mbar
Airway pressure safety: ≤ 74 mbar
Manometer accuracy: 0 to 60 mbar Deviation ±5%
Trigger sensitivity: -2MBAR standard deviation ± 5%
Ventilation tube: 20 to 60 mb

Patient valve resistance:
- Inspiration <6 mbar at 30, 60 l/min
- Expiration <6 mbar at 30, 60 l/min
- Emergency air intake <6 mbar at 15, 30 l/min
Respiratory compliance: 100 ml/cmH2O
Voice alarm silence time ≤120s
Language: supports up to 5 languages

Regulations: EN794, ISO9001, ISO13485, EN1789

Storage:
Keep the device in a dry place and do not expose it to direct sunlight
Observe the temperatures recommended by the device manufacturer
Refer to the user manual for further information

Maintenance and cleaning:
Refer to the instruction manual for further information
Clean the instrument with a cloth slightly dampened with a simple disinfectant
Attention: Do not immerse the device in water or liquids

Included items:
1 6000S pulmonary ventilator
1 Reusable breathing circuit
1 Breathing valve
1 Ventilation tube (EU standard)
1 Large hook for silicone mask
1 Reusable silicone adult mask Size 5
1 Silicone head harness (for adult)
1 PEEP valve
1 Power adapter (EU standard)
1 AC power cord (EU standard)
1 User Manual

Codice CFS: SE15562

Marca: Amoul

Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.

LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).

In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.

In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.

Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:

  • Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
  • Di uguale qualità rispetto ad un campione o modello analogo
  • Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
  • Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore

Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.

Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.

Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:

  • non comprendenti imballi, accessori e manualistiche originali.
  • ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
  • la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.

Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.

Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.

Sede Centrale (indirizzo geografico presentazione reclami):

CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608

P.IVA: 01883060491 - CCIAA e REA: 205156

Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30

→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica

In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.


Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.

Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.

Termine per l'esercizio del diritto di recesso

Il periodo di recesso scade dopo 14 giorni:

  • dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
  • nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.

Modalità di esercizio del diritto di recesso

Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.

La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.

Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.

Restituzione dei prodotti

Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.

Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.

La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.

Stato dei prodotti restituiti

Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.

Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.

La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.

Rimborso

In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.

Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.

CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.

Esclusioni dal diritto di recesso

Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:

  • ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
  • ai beni confezionati su misura o chiaramente personalizzati;
  • agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.

Foro competente

Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.

Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta