Tablet-format portable electrocardiograph for acquiring, analyzing, and storing 12-lead ECG traces.
7-inch color touch-screen liquid crystal display allows for simultaneous viewing of information in both portrait and landscape orientation, such as:
ECG Trace
- 12 leads in pre- and post-acquisition
- heart rate
- ECG interpretation
- cardiac rhythm analysis from 30 to 300 seconds for a single rhythm lead and from 30 to 300 seconds for three selectable rhythm leads
- trace freezing up to 300 seconds
- filters used
- ECG sensitivity
- disconnected leads
General Menu
- analysis mode
- patient data
- date and time
- battery charge status indicator
- SD card presence symbol
- alarm messages
- exam saving
Operating mode selectable between manual, automatic, and stored exam loading.
Accurate and reliable interpretation thanks to the Biocare CardioPro ECG analysis program, compliant with strict CSE database evaluation standards, to ensure high accuracy and reliability in both measurements and ECG trace interpretation.
Sensitivity and specificity of QRS detection and analysis equal to 99%.
Complete program of digital and self-adaptive filters allows for the elimination of artifacts without distortion of the ECG trace; the 0.01 Hz frequency of the high-pass filter contributes to distortion-free measurements and analysis of the ST segment.
The exclusive pediatric analysis software module, with a 250 Hz low-pass filter, meets the latest 2007 AHA/ACC/HRS standards.
Application of the latest Minnesota codes.
Pacemaker pulse recognition function.
Up to 300 seconds of frozen trace on screen, as a practical aid for analyzing events in critical patients such as the elderly and restless children.
Operating guide on the color display to verify ECG trace acquisition procedures.
Measurement parameters: - heart rate - PR interval - QRS duration - QT/QTC interval - P/QRS/T axes - RV5/SV1 amplitude - RV5+SV1 amplitude;
Recording format: 3x4 + 1 rhythm lead - 3x4 + 3 rhythm leads - 6x2 + 1 rhythm lead - 12x1
Generatable reports:
- Simple: 12-lead ECG trace, patient data, PR interval, QRS interval, QT/QTc interval, P/QRS/Ti axis, RV5/SV1 and RV5+SV1 amplitude, interpretation analysis
- Detailed: 12-lead ECG trace, patient data, PR interval, QRS interval, QT/QTc interval, P/QRS/Ti axis, RV5/SV1 and RV5+SV1 amplitude, interpretation analysis, amplitudes and duration (P, P, Q, R, R, S, T waves), STJ for the 12 leads
Data memory:
- possibility to save up to 3,000 exams in the device memory
- on micro SD card with capacity up to 16 GB (optional)
By connecting to the ECG workstation in wireless mode, it is possible to upload ECG traces and download exam reports:
- to transfer ECG data from the iE10 Tablet to a PC via WIFI, it is necessary to use an external router with an active WIFI network;
- to acquire and transfer the ECG to the iE10 Tablet, it is necessary to purchase separately 1 x 12-lead ECG Acquisition Bluetooth Module (optional) which will use the wireless connection to send the exam to the PC.
Data can be printed via connection to an external laser printer and can in any case be transferred via USB connection or SD card.
Equipped with an integrated rechargeable Lithium-ion battery, with 4 hours of autonomy in continuous use.
Supplied ECG-1000 software:
Electrocardiogram analysis software for Biocare iE Series and ECG8080 ECGs
Program that allows for data acquisition and analysis of electrocardiographic traces.
- Variety of analysis reports to meet different requirements
- High-precision ruler for measurement and re-analysis
- Possibility of auto-analysis and processing
- Report editing function
- Central control system that allows for full archiving of electronic medical records to compare with the previous exam
Technical features:
Dimensions (LxWxH): 194 x 117 x 25 mm
Weight: 0.5 kg
Display type: 7" LCD touch screen
Screen resolution: 1280 x 800 pixels
Patient type: Adults and children
Measured data: HR (heart rate) - QRS complex duration - PR interval - QT/QTc interval - P/QRS/Ti axis - RV5/SV1 and RV5+SV1 amplitude - Amplitudes and duration (P, P, Q, R, R, S, T waves) - STJ for the 12 leads
Heart rate range: 30 ̴ 300 bpm
Acquisition mode: 12 standard leads
A/D conversion: 24 bit
Sampling rate: 1,000 samples/s
Dynamic range: ± 9 mV
Frequency response: 0.05 Hz ̴ 250 Hz
Common Mode Rejection: > 115 dB
Input circuit: Floating
Input impedance: ≥ 50 MΩ
CIR input current: ≤ 0.1 μA
Patient leakage current: < 10 μA
Time constant: ≥ 3.2 s
Noise level: < 15 μVp-
Sensitivity threshold: ≤ 20 μVp-p
Calibration voltage: 1 mV ± 3
Sensitivity: 8 levels (1.25, 2.5 , 5 , 10 , 20 , 10/5 , 20/10) mm/mV ±3
Filter setting: - EMG: 25/35/75/100/150/250 Hz - - Baseline: 0.01/0.02/0.05/0.35/0.5/0.8 Hz
AC filter
50 Hz, 60 Hz
Special detection functions: Absence of leads - AC interference - Baseline interference - EMG interference
Information displayed on screen: ECG waveform - Heart rate - Lead connection - Time - Recording mode - Filters - Sensitivity - System prompts - Alarm messages - Battery indicator - Power indicator - SD card symbol
Waveform display: 6x2 + 1 rhythm lead - 12x1
Trace recording: Possibility of connection to an external laser printer
Recording speed: (6.25, 12.5 , 25 , 50) mm/s
Measurements and interpretation: Biocare CardPro ECG analysis program
Encoding used: Minnesota
Operating mode: Automatic - Manual - Exam loading
DEMO mode: Normal ECG - ECG with arrhythmia
Rhythm analysis: single rhythm lead: 30 ̴ 300 seconds - 3 rhythm leads: 30 ̴ 100 seconds for each lead
Extended printing during arrhythmic events: Supports printing of the extended waveform in arrhythmia with automatic mode
Waveform freeze function: Up to 300 seconds
Pacemaker detection: Weak, Normal, Best
Auto-save of report: Report preview before printing
File formats: JPEG, XML, DICOM, PDF, ECG
Alarm system: Voice and visual signal for: disconnected lead - low battery
Patient data setting: Registration number - Name - Sex - Date of birth - Height - Weight - Blood pressure - Ethnicity - Pacemaker - Medications - Doctor - Technician - Room number - User-defined
Language: Italian, English
Local memory capacity: More than 3,000 files
Report type: Simple, detailed, median beats
Recording formats: - 3x4 + 1 rhythm lead - 3x4 + 3 rhythm leads - 6x2 + 1 rhythm lead - 12x1
Patient cable input: For connection to the 10-bipolar lead ECG cable
Micro SD input: 16 GB TF for data transfer (optional)
USB inputs: For data transfer - For barcode scanner (patient data entry) - For connection to an external printer
Mains power: AC, 100 V ̴ 240 V, 50 Hz / 60 Hz , 12 W
DC adapter: 5 V, 2.4 A
Battery type: Rechargeable Lithium, 3.7 V, 5800 mAh
Battery life: 4 hours in continuous operation
Battery charging time: Approx. 4 hours from a fully discharged condition
Communication with Biocare ECG-1000 software on PC with Microsoft Windows XP/Vista /Win7/Win8/Win10 operating systems
Clinical validation
Clinical validation conducted through comparison with an equivalent Biocare ECG-1260 device, with proven evidence on a significant sample of patients and doctors.
The iE 10 device has passed tests according to EN 60601-1, EN 60601-1-2, IEC 60601-2-25 standards.
Included:
1 iE 10 portable ECG unit
1 ECG-1000 software
10 Disposable electrodes
1 10-bipolar lead patient cable
1 Biocare ECG tablet carrying bag
1 AC power supply unit Input: 100-240 V - DC output: 5V 2.4 A
1 Multilingual instruction manual
1 24-month warranty for manufacturing defects, excluding parts subject to wear and the 12-lead ECG cable.
Optional upon request:
12-lead ECG Acquisition Bluetooth Module for IE10
Related categories:
🔘 Disposable ECG electrodes
📈 ECG chart paper
🔌 Patient cables for ECG and Holter
♻️ Reusable ECG accessories
👜 Bags, Gel and other ECG accessories
Codice CFS: DG0009903
Marca: Biocare
EAN: 937683413855
Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.
LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).
In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.
Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:
- Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
- Di uguale qualità rispetto ad un campione o modello analogo
- Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
- Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore
Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.
Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.
Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:
- non comprendenti imballi, accessori e manualistiche originali.
- ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
- la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.
Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.
Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.
Sede Centrale (indirizzo geografico presentazione reclami):
CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608
P.IVA: 01883060491 - CCIAA e REA: 205156
Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30
→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica
In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.
Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.
Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.
Termine per l'esercizio del diritto di recesso
Il periodo di recesso scade dopo 14 giorni:
- dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
- nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.
Modalità di esercizio del diritto di recesso
Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.
La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.
Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.
Restituzione dei prodotti
Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.
Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.
La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.
Stato dei prodotti restituiti
Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.
Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.
La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.
Rimborso
In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.
Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.
CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.
Esclusioni dal diritto di recesso
Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:
- ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
- ai beni confezionati su misura o chiaramente personalizzati;
- agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.
Foro competente
Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.
Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta
Brand: Biocare
Biocare iE10 Tablet ECG - 12-channel Interpretive Electrocardiograph + PC Software
7" Touch Screen display - 3,000-exam storage capacity in device memory - USB connection for data transfer - Built-in rechargeable Lithium-ion battery, with 4-hour battery life in continuous use - ECG-1000 interpretive software in Italian included
(IVA esclusa)
(IVA esclusa)
€1242,15 (IVA 5% inclusa)
Disponibile - 2 - Delivery in 5 days
Tablet-format portable electrocardiograph for acquiring, analyzing, and storing 12-lead ECG traces.
7-inch color touch-screen liquid crystal display allows for simultaneous viewing of information in both portrait and landscape orientation, such as:
ECG Trace
- 12 leads in pre- and post-acquisition
- heart rate
- ECG interpretation
- cardiac rhythm analysis from 30 to 300 seconds for a single rhythm lead and from 30 to 300 seconds for three selectable rhythm leads
- trace freezing up to 300 seconds
- filters used
- ECG sensitivity
- disconnected leads
General Menu
- analysis mode
- patient data
- date and time
- battery charge status indicator
- SD card presence symbol
- alarm messages
- exam saving
Operating mode selectable between manual, automatic, and stored exam loading.
Accurate and reliable interpretation thanks to the Biocare CardioPro ECG analysis program, compliant with strict CSE database evaluation standards, to ensure high accuracy and reliability in both measurements and ECG trace interpretation.
Sensitivity and specificity of QRS detection and analysis equal to 99%.
Complete program of digital and self-adaptive filters allows for the elimination of artifacts without distortion of the ECG trace; the 0.01 Hz frequency of the high-pass filter contributes to distortion-free measurements and analysis of the ST segment.
The exclusive pediatric analysis software module, with a 250 Hz low-pass filter, meets the latest 2007 AHA/ACC/HRS standards.
Application of the latest Minnesota codes.
Pacemaker pulse recognition function.
Up to 300 seconds of frozen trace on screen, as a practical aid for analyzing events in critical patients such as the elderly and restless children.
Operating guide on the color display to verify ECG trace acquisition procedures.
Measurement parameters: - heart rate - PR interval - QRS duration - QT/QTC interval - P/QRS/T axes - RV5/SV1 amplitude - RV5+SV1 amplitude;
Recording format: 3x4 + 1 rhythm lead - 3x4 + 3 rhythm leads - 6x2 + 1 rhythm lead - 12x1
Generatable reports:
- Simple: 12-lead ECG trace, patient data, PR interval, QRS interval, QT/QTc interval, P/QRS/Ti axis, RV5/SV1 and RV5+SV1 amplitude, interpretation analysis
- Detailed: 12-lead ECG trace, patient data, PR interval, QRS interval, QT/QTc interval, P/QRS/Ti axis, RV5/SV1 and RV5+SV1 amplitude, interpretation analysis, amplitudes and duration (P, P, Q, R, R, S, T waves), STJ for the 12 leads
Data memory:
- possibility to save up to 3,000 exams in the device memory
- on micro SD card with capacity up to 16 GB (optional)
By connecting to the ECG workstation in wireless mode, it is possible to upload ECG traces and download exam reports:
- to transfer ECG data from the iE10 Tablet to a PC via WIFI, it is necessary to use an external router with an active WIFI network;
- to acquire and transfer the ECG to the iE10 Tablet, it is necessary to purchase separately 1 x 12-lead ECG Acquisition Bluetooth Module (optional) which will use the wireless connection to send the exam to the PC.
Data can be printed via connection to an external laser printer and can in any case be transferred via USB connection or SD card.
Equipped with an integrated rechargeable Lithium-ion battery, with 4 hours of autonomy in continuous use.
Supplied ECG-1000 software:
Electrocardiogram analysis software for Biocare iE Series and ECG8080 ECGs
Program that allows for data acquisition and analysis of electrocardiographic traces.
- Variety of analysis reports to meet different requirements
- High-precision ruler for measurement and re-analysis
- Possibility of auto-analysis and processing
- Report editing function
- Central control system that allows for full archiving of electronic medical records to compare with the previous exam
Technical features:
Dimensions (LxWxH): 194 x 117 x 25 mm
Weight: 0.5 kg
Display type: 7" LCD touch screen
Screen resolution: 1280 x 800 pixels
Patient type: Adults and children
Measured data: HR (heart rate) - QRS complex duration - PR interval - QT/QTc interval - P/QRS/Ti axis - RV5/SV1 and RV5+SV1 amplitude - Amplitudes and duration (P, P, Q, R, R, S, T waves) - STJ for the 12 leads
Heart rate range: 30 ̴ 300 bpm
Acquisition mode: 12 standard leads
A/D conversion: 24 bit
Sampling rate: 1,000 samples/s
Dynamic range: ± 9 mV
Frequency response: 0.05 Hz ̴ 250 Hz
Common Mode Rejection: > 115 dB
Input circuit: Floating
Input impedance: ≥ 50 MΩ
CIR input current: ≤ 0.1 μA
Patient leakage current: < 10 μA
Time constant: ≥ 3.2 s
Noise level: < 15 μVp-
Sensitivity threshold: ≤ 20 μVp-p
Calibration voltage: 1 mV ± 3
Sensitivity: 8 levels (1.25, 2.5 , 5 , 10 , 20 , 10/5 , 20/10) mm/mV ±3
Filter setting: - EMG: 25/35/75/100/150/250 Hz - - Baseline: 0.01/0.02/0.05/0.35/0.5/0.8 Hz
AC filter
50 Hz, 60 Hz
Special detection functions: Absence of leads - AC interference - Baseline interference - EMG interference
Information displayed on screen: ECG waveform - Heart rate - Lead connection - Time - Recording mode - Filters - Sensitivity - System prompts - Alarm messages - Battery indicator - Power indicator - SD card symbol
Waveform display: 6x2 + 1 rhythm lead - 12x1
Trace recording: Possibility of connection to an external laser printer
Recording speed: (6.25, 12.5 , 25 , 50) mm/s
Measurements and interpretation: Biocare CardPro ECG analysis program
Encoding used: Minnesota
Operating mode: Automatic - Manual - Exam loading
DEMO mode: Normal ECG - ECG with arrhythmia
Rhythm analysis: single rhythm lead: 30 ̴ 300 seconds - 3 rhythm leads: 30 ̴ 100 seconds for each lead
Extended printing during arrhythmic events: Supports printing of the extended waveform in arrhythmia with automatic mode
Waveform freeze function: Up to 300 seconds
Pacemaker detection: Weak, Normal, Best
Auto-save of report: Report preview before printing
File formats: JPEG, XML, DICOM, PDF, ECG
Alarm system: Voice and visual signal for: disconnected lead - low battery
Patient data setting: Registration number - Name - Sex - Date of birth - Height - Weight - Blood pressure - Ethnicity - Pacemaker - Medications - Doctor - Technician - Room number - User-defined
Language: Italian, English
Local memory capacity: More than 3,000 files
Report type: Simple, detailed, median beats
Recording formats: - 3x4 + 1 rhythm lead - 3x4 + 3 rhythm leads - 6x2 + 1 rhythm lead - 12x1
Patient cable input: For connection to the 10-bipolar lead ECG cable
Micro SD input: 16 GB TF for data transfer (optional)
USB inputs: For data transfer - For barcode scanner (patient data entry) - For connection to an external printer
Mains power: AC, 100 V ̴ 240 V, 50 Hz / 60 Hz , 12 W
DC adapter: 5 V, 2.4 A
Battery type: Rechargeable Lithium, 3.7 V, 5800 mAh
Battery life: 4 hours in continuous operation
Battery charging time: Approx. 4 hours from a fully discharged condition
Communication with Biocare ECG-1000 software on PC with Microsoft Windows XP/Vista /Win7/Win8/Win10 operating systems
Clinical validation
Clinical validation conducted through comparison with an equivalent Biocare ECG-1260 device, with proven evidence on a significant sample of patients and doctors.
The iE 10 device has passed tests according to EN 60601-1, EN 60601-1-2, IEC 60601-2-25 standards.
Included:
1 iE 10 portable ECG unit
1 ECG-1000 software
10 Disposable electrodes
1 10-bipolar lead patient cable
1 Biocare ECG tablet carrying bag
1 AC power supply unit Input: 100-240 V - DC output: 5V 2.4 A
1 Multilingual instruction manual
1 24-month warranty for manufacturing defects, excluding parts subject to wear and the 12-lead ECG cable.
Optional upon request:
12-lead ECG Acquisition Bluetooth Module for IE10
Related categories:
🔘 Disposable ECG electrodes
📈 ECG chart paper
🔌 Patient cables for ECG and Holter
♻️ Reusable ECG accessories
👜 Bags, Gel and other ECG accessories
Codice CFS: DG0009903
Marca: Biocare
EAN: 937683413855
Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.
LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).
In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.
Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:
- Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
- Di uguale qualità rispetto ad un campione o modello analogo
- Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
- Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore
Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.
Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.
Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:
- non comprendenti imballi, accessori e manualistiche originali.
- ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
- la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.
Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.
Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.
Sede Centrale (indirizzo geografico presentazione reclami):
CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608
P.IVA: 01883060491 - CCIAA e REA: 205156
Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30
→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica
In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.
Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.
Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.
Termine per l'esercizio del diritto di recesso
Il periodo di recesso scade dopo 14 giorni:
- dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
- nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.
Modalità di esercizio del diritto di recesso
Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.
La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.
Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.
Restituzione dei prodotti
Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.
Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.
La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.
Stato dei prodotti restituiti
Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.
Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.
La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.
Rimborso
In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.
Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.
CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.
Esclusioni dal diritto di recesso
Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:
- ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
- ai beni confezionati su misura o chiaramente personalizzati;
- agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.
Foro competente
Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.
Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta
Biocare iE10 Tablet ECG - 12-channel Interpretive Electrocardiograph + PC Software

Articoli simili da considerare
Altri utenti hanno acquistato anche