Europa B Evo is an autoclave developed through a collaboration between Tecno-Gaz’s research department and other major external development facilities.
Europa B Evo is indispensable in all medical and dental facilities and all sectors requiring safe sterilization of all materials:
hollow, porous, solid, unwrapped and wrapped.
Europa B Evo represents the continuity of a success that Tecno-Gaz has enjoyed for years; in fact, thousands of professionals use Tecno-Gaz autoclaves with great satisfaction.

Applied safety features
- Certified safety valve.
- PED on sterilization chambers.
- Chamber insulation with certified ceramic material.
- The new control panel with a blue display has a striking aesthetic impact and great modernity.
- The new filling connections, which fit flush with the front of the autoclave, represent a true innovation.

Europa B Evo is indispensable in all medical and dental facilities and in all sectors where safe sterilization is required for all materials, hollow, porous, solid, unwrapped and wrapped.
Europa B Evo is the continuity of a success that Tecno-Gaz has enjoyed for years; in fact, thousands of professionals use Tecno-Gaz autoclaves with great satisfaction.

Europa B Evo features

- Circular chamber in treated AISI 304 stainless steel
- Maximum load per cycle: 5 kg
- 3 door safety features: electromagnetic, electrical, and dynamic
- Control board integrated into the panel
- Graphic display
- Automatic pressure alignment system
- Water filling with pump system and automatic full-tank stop
- Door gasket to ensure maximum durability
- Rear panel preparation, with the option for automatic water filling and drainage
- Forced ventilation system integrated into the unit
- Protected tray holder that prevents contact between the load and the chamber.

The P.I.D. system
The primary commitment of a company like Tecno-Gaz is to create a product with unique solutions, features, and characteristics that ensure maximum reliability and safety for the user.
Our research departments, with the support and collaboration of external bodies, have created an extraordinary system that has been applied for the first time to our autoclaves; this innovative device is the P.I.D.
P.I.D. is an acronym for Proportional-Integral-Derivative and is the ultimate expression of closed-loop control. The structure of this sophisticated control is simple and flexible. P.I.D. ensures constant control and monitoring of the autoclave's entire functional system, intervening automatically in the event of anomalies regarding incorrect technical and electronic parameters.
A device that acts like "a real technician" with diagnostic and real-time intervention capabilities.
A solution that limits anomalies and alarms, ensuring maximum reliability and minimizing any machine downtime.

Sterilization
Autoclaves capable of sterilizing Type B loads

There are many models of autoclaves with different characteristics and features.
Every medical facility or practice must adopt the model most suitable for its operational needs, as dictated by the loads it needs to sterilize.
Regarding loads, EN 13060 has precisely defined the classification, clarifying that the following materials are considered Type B loads:

Porous bodies
Porous bodies are simple or composite materials that can absorb fluids (fabrics, gowns, gauze, dressings, etc...)

Hollow bodies
Hollow bodies are materials or devices with cavities, obstructions, etc. These are divided into two classes defined precisely through a careful description of the ratio between length and diameter.
We set out below some general reference concepts.

Type B: cannulas, tubes, or devices with significant passages
Type A: turbines, handpieces, and devices with blind holes or small dimensions.
Given this, it is evident that all facilities where the aforementioned materials are used must opt for a state-of-the-art autoclave capable of ensuring safe sterilization for Type B loads. Tecno-Gaz S.p.A. produces a wide range of autoclaves that can guarantee the correct sterilization of all types of materials, particularly Type B loads:

Europa B Evo: the autoclave with a fractionated vacuum system, complete with various devices.
Autoclaves that guarantee safe sterilization

Constantly monitored cycles
The Europa B Evo – Europa B Evo 24 autoclave line comes complete with a device for constant control and monitoring of sterilization cycles. Any type of anomaly is detected, and if it compromises the sterilization cycle, the unit is immediately blocked and the anomaly is displayed via a message.

Fixed, non-tamperable cycles
All cycles are fixed and always ensure the safe sterilization of the treated materials. There is no possibility for operators to intervene or tamper with the cycles, which avoids any type of possible human error.

All cycles ensure the sterilization of Type B loads
All sterilization cycles have the fractionated vacuum system, controls, and parameters that ensure the sterilization of Type B loads. Even an incorrect selection of the desired cycle always ensures safe sterilization on any type of material treated.

Ergonomics and ease of use
Just press one button to select the cycle and another button to start the complete process.
It is impossible to make mistakes, impossible to select a cycle that does not ensure correct sterilization; any operational error is signaled via error messages.
The autoclave can be used by multiple people without the possibility of causing damage or problems. Tecno-Gaz has sought to provide maximum operational safety in this important aspect as well.

The sterilization process

The sterilization process consists of several phases, and for each point, Tecno-Gaz has chosen to adopt cutting-edge technical solutions.

Vacuum is the first phase of the cycle and is crucial for correct sterilization. We ensure an excellent result by adopting a high-quality pump that allows for the removal of air pockets even in hollow and porous bodies.
Preheating is the phase in which the sterilization cycle parameters—temperature and pressure—are stabilized. We adopt a preheating system with a heating element designed to minimize the duration of this phase.
Exposure time is the period during which all microorganisms are eradicated; pressure, temperature, and time must be monitored perfectly. We can count on a double-probe system and microprocessor control, further managed by the exclusive P.I.D. system.
Drying is the important final phase of the sterilization cycle. Perfect drying ensures the sterile maintenance of the instruments. Tecno-Gaz adopts a combined vacuum + heat system that ensures perfect drying of the sterilized materials, both unwrapped and wrapped.

The importance of vacuum

Why vacuum
After finishing loading the autoclave and closing the door, ambient air is trapped inside the chamber, which, due to different physical elasticity, does not mix with the steam produced. These "air pockets" remain "cold," therefore they are an impediment to the correct and safe sterilization of the treated materials. It is important to adopt a forced expulsion system for these air pockets.

Vacuum systems
There are several vacuum systems applicable to autoclaves. The most advanced and safe vacuum method to achieve safe sterilization on all materials, including hollow and porous ones, is the fractionated vacuum.

Fractionated vacuum
Europa B Evo – Europa B Evo 24 adopt the fractionated vacuum system. The fractionated vacuum is a system that alternates phases of negative pressure with phases of positive pressure and is implemented at the start of each sterilization cycle. This method is the ultimate technical expression of vacuum and ensures the expulsion of air pockets in all materials, even in hollow and porous ones.

Cycles

Fixed temperatures
The temperatures set on our autoclave cycles are 134°C and 121°C. The 134°C cycles are normally used for the sterilization of solid and ferrous materials. The 121°C cycles are used for thermoplastics, fabrics, and sensitive materials. Always sterilize materials by following the indications provided by the device manufacturer.

Simplicity of use
Choosing and selecting a sterilization cycle on Tecno-Gaz autoclaves is very simple and intuitive. One key allows you to scroll and view data relating to each cycle on the large display, allowing you to identify the most suitable cycle; then, it is sufficient to press one button to automatically start the entire sterilization cycle without having to worry about anything else. For any error or alarm, messages and LED indicators will call your attention.

Completely automatic cycles
All cycles are completely automatic; all phases are managed by an advanced board complete with a powerful microprocessor. Every phase (vacuum, preheating, exposure time, drying) is monitored, supported, and managed automatically. There is no human involvement in the execution of the cycles.

Wide range of operating cycles
Europa B Evo and Europa B Evo 24 autoclaves are equipped with:
1 sterilization cycle at 134°C for unwrapped and wrapped materials.
1 sterilization cycle at 121°C for unwrapped and wrapped materials.
1 flash sterilization cycle for rapid cycles.
1 specific prion sterilization cycle for C&J disease.

Operator-free cycles with automatic shutdown
All sterilization cycles have an automatic function that, in the absence of an operator at the end of the cycle, starts an anti-condensation phase and an automatic shutdown. This system saves energy and keeps the equipment safe.

Test cycles
Our autoclaves come complete with test cycles for periodic control of the equipment using physical and functional systems.
Helix test to evaluate vacuum capability in porous bodies.
Bowie & Dick test to evaluate vacuum capability in bodies.
Vacuum test to evaluate the vacuum maintenance capability.

Safety for operators

Door safety
We have applied three safety devices to the door:
The first is mechanical-electromagnetic: it activates the moment the sterilization cycle is started and completely blocks the door from opening. This device can be released at the end of the cycle by activating a specific button, and only when positive pressure is close to zero.
The second is electrical: it activates automatically the moment there is a clear attempt at forced opening of the machine.
The third is dynamic: the gasket is made with a new concept that does not allow the door to open in case of pressure inside the chamber.

Applied safety features
Certified safety valve.
PED on sterilization chambers.
Chamber insulation with certified ceramic material.

Flexible autoclaves

For a leading company like ours, the first objective is to create "flexible" devices that can be adapted to the individual needs of operators to allow for operational ease and savings in time and money. During the project development phase, it becomes a priority for our technicians to study technical solutions that can guarantee this all-important feature. The Europa B Evo – Europa B Evo 24 autoclaves can count on a series of solutions that allow the operator to set up the autoclave according to their own operational needs.

Water tank filling: prepare your autoclaves according to your needs
You can choose how to set up your autoclave.
Europa B Evo is already ready to:
Have autonomous operation, using the water from the internal tanks and manually loading/unloading pure and used water.
Be connected directly to the water mains, via a specific reverse osmosis system (mod. Pura), to have a continuous water supply and automatic drainage, without wasting time on manual operations.


Advice
For those who use the autoclave constantly and do not want the implications related to purchasing distilled water and managing tank filling and drainage, we recommend adopting the Pura system; you will save time and money and protect the autoclave because you will always have controlled and suitable water.

Internal machine tanks
All autoclaves have a pure water tank and a used water tank inside the unit. Each tank is equipped with sensors to signal minimum and maximum levels.

Filling the tanks
If the autoclave is connected to the mod. Pura device, the tanks fill automatically, whereas if you intend to use it autonomously, water filling is done manually. Tecno-Gaz autoclaves, to facilitate this operation, are equipped with a filling method using a pump and a full-tank detection system that stops the water flow. This important option, standard on all models in the line, avoids human error due to overfilling and reduces operator effort. The autoclave is also set up for manual tank filling in case the fill pump does not work.

Chamber and load
All Tecno-Gaz autoclave chambers are built with special stainless steel. They are produced using advanced industrial systems and subjected to strict control and individual testing procedures.

Load and dimensions
A parameter of great interest to buyers is the chamber volume, as it is used as the sole parameter to evaluate how much load the autoclave can sterilize.
In truth, we can find autoclaves with larger chambers than others, but with the capacity to sterilize a smaller amount of load. All this is determined by technical choices: heating system, heating element power, etc...
Always evaluate carefully not only the volume of the chamber but also and above all the load quantity declared by the manufacturers, which is normally around 750/1,000 g per tray.

Rich standard equipment
We believe that every autoclave should be supplied with all the equipment needed to perform normal daily operations and those accessories needed for the management and control of the equipment itself. Therefore, Tecno-Gaz autoclaves are offered already complete with all possible accessories and preparations.
Integrated printer on all models: ensures the recording of sterilization cycles and allows for the formalization of the vacuum test.
Preparation for water mains connection: all autoclaves are prepared for water mains connection via Pura.
Included accessories: 1 closed tray holder, 4 aluminum tray holders, 1 dual-function key for tray extraction and door adjustment, water filling and drainage hoses, sponge for chamber cleaning.

Technical Characteristics:
Power supply: 230V-50/60 Hz
External dimensions (mm): 510x590x390
Tray dimensions (W x H x D) (mm): 184 x 17 x 286
Weight (kg): 54
Absorption: 1,700 W
Chamber dimensions (mm): Ø 245x320
Thermal printer

Included:
1 closed tray holder
4 aluminum trays
1 dual-use key for extracting trays and adjusting the door
1 water filling and drainage hose and sponge for cleaning

Codice CFS: ST0001534

Marca: Tecno-gaz

Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.

LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).

In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.

In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.

Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:

  • Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
  • Di uguale qualità rispetto ad un campione o modello analogo
  • Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
  • Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore

Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.

Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.

Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:

  • non comprendenti imballi, accessori e manualistiche originali.
  • ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
  • la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.

Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.

Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.

Sede Centrale (indirizzo geografico presentazione reclami):

CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608

P.IVA: 01883060491 - CCIAA e REA: 205156

Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30

→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica

In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.


Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.

Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.

Termine per l'esercizio del diritto di recesso

Il periodo di recesso scade dopo 14 giorni:

  • dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
  • nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.

Modalità di esercizio del diritto di recesso

Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.

La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.

Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.

Restituzione dei prodotti

Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.

Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.

La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.

Stato dei prodotti restituiti

Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.

Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.

La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.

Rimborso

In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.

Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.

CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.

Esclusioni dal diritto di recesso

Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:

  • ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
  • ai beni confezionati su misura o chiaramente personalizzati;
  • agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.

Foro competente

Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.

Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta

Codice prodotto: ST0001534

Tecno Gaz Europa B EVO Autoclave - Class B 15 L

+ Special 24-month warranty, online course on sterilization, and free delivery of operating protocols

Regular price €3.087,50

(IVA esclusa)

Sale price €3.087,50

(IVA esclusa)

€3766,75 (IVA 22% inclusa)

Shipping calculated at checkout.

Acquistabile in renting se titolari di p.iva da almeno due anni: Rate a partire da 61,80€ con

Paga fino a 12 rate senza costi con

Ordinabile - Spedizione in 15 giorni

Spedizione gratuita
Recommend

Shipping in 24/48h for in-stock products

Technical support Spare parts, calibration services, etc...

Descrizione
Garanzie e Resi
Recensioni

Europa B Evo is an autoclave developed through a collaboration between Tecno-Gaz’s research department and other major external development facilities.
Europa B Evo is indispensable in all medical and dental facilities and all sectors requiring safe sterilization of all materials:
hollow, porous, solid, unwrapped and wrapped.
Europa B Evo represents the continuity of a success that Tecno-Gaz has enjoyed for years; in fact, thousands of professionals use Tecno-Gaz autoclaves with great satisfaction.

Applied safety features
- Certified safety valve.
- PED on sterilization chambers.
- Chamber insulation with certified ceramic material.
- The new control panel with a blue display has a striking aesthetic impact and great modernity.
- The new filling connections, which fit flush with the front of the autoclave, represent a true innovation.

Europa B Evo is indispensable in all medical and dental facilities and in all sectors where safe sterilization is required for all materials, hollow, porous, solid, unwrapped and wrapped.
Europa B Evo is the continuity of a success that Tecno-Gaz has enjoyed for years; in fact, thousands of professionals use Tecno-Gaz autoclaves with great satisfaction.

Europa B Evo features

- Circular chamber in treated AISI 304 stainless steel
- Maximum load per cycle: 5 kg
- 3 door safety features: electromagnetic, electrical, and dynamic
- Control board integrated into the panel
- Graphic display
- Automatic pressure alignment system
- Water filling with pump system and automatic full-tank stop
- Door gasket to ensure maximum durability
- Rear panel preparation, with the option for automatic water filling and drainage
- Forced ventilation system integrated into the unit
- Protected tray holder that prevents contact between the load and the chamber.

The P.I.D. system
The primary commitment of a company like Tecno-Gaz is to create a product with unique solutions, features, and characteristics that ensure maximum reliability and safety for the user.
Our research departments, with the support and collaboration of external bodies, have created an extraordinary system that has been applied for the first time to our autoclaves; this innovative device is the P.I.D.
P.I.D. is an acronym for Proportional-Integral-Derivative and is the ultimate expression of closed-loop control. The structure of this sophisticated control is simple and flexible. P.I.D. ensures constant control and monitoring of the autoclave's entire functional system, intervening automatically in the event of anomalies regarding incorrect technical and electronic parameters.
A device that acts like "a real technician" with diagnostic and real-time intervention capabilities.
A solution that limits anomalies and alarms, ensuring maximum reliability and minimizing any machine downtime.

Sterilization
Autoclaves capable of sterilizing Type B loads

There are many models of autoclaves with different characteristics and features.
Every medical facility or practice must adopt the model most suitable for its operational needs, as dictated by the loads it needs to sterilize.
Regarding loads, EN 13060 has precisely defined the classification, clarifying that the following materials are considered Type B loads:

Porous bodies
Porous bodies are simple or composite materials that can absorb fluids (fabrics, gowns, gauze, dressings, etc...)

Hollow bodies
Hollow bodies are materials or devices with cavities, obstructions, etc. These are divided into two classes defined precisely through a careful description of the ratio between length and diameter.
We set out below some general reference concepts.

Type B: cannulas, tubes, or devices with significant passages
Type A: turbines, handpieces, and devices with blind holes or small dimensions.
Given this, it is evident that all facilities where the aforementioned materials are used must opt for a state-of-the-art autoclave capable of ensuring safe sterilization for Type B loads. Tecno-Gaz S.p.A. produces a wide range of autoclaves that can guarantee the correct sterilization of all types of materials, particularly Type B loads:

Europa B Evo: the autoclave with a fractionated vacuum system, complete with various devices.
Autoclaves that guarantee safe sterilization

Constantly monitored cycles
The Europa B Evo – Europa B Evo 24 autoclave line comes complete with a device for constant control and monitoring of sterilization cycles. Any type of anomaly is detected, and if it compromises the sterilization cycle, the unit is immediately blocked and the anomaly is displayed via a message.

Fixed, non-tamperable cycles
All cycles are fixed and always ensure the safe sterilization of the treated materials. There is no possibility for operators to intervene or tamper with the cycles, which avoids any type of possible human error.

All cycles ensure the sterilization of Type B loads
All sterilization cycles have the fractionated vacuum system, controls, and parameters that ensure the sterilization of Type B loads. Even an incorrect selection of the desired cycle always ensures safe sterilization on any type of material treated.

Ergonomics and ease of use
Just press one button to select the cycle and another button to start the complete process.
It is impossible to make mistakes, impossible to select a cycle that does not ensure correct sterilization; any operational error is signaled via error messages.
The autoclave can be used by multiple people without the possibility of causing damage or problems. Tecno-Gaz has sought to provide maximum operational safety in this important aspect as well.

The sterilization process

The sterilization process consists of several phases, and for each point, Tecno-Gaz has chosen to adopt cutting-edge technical solutions.

Vacuum is the first phase of the cycle and is crucial for correct sterilization. We ensure an excellent result by adopting a high-quality pump that allows for the removal of air pockets even in hollow and porous bodies.
Preheating is the phase in which the sterilization cycle parameters—temperature and pressure—are stabilized. We adopt a preheating system with a heating element designed to minimize the duration of this phase.
Exposure time is the period during which all microorganisms are eradicated; pressure, temperature, and time must be monitored perfectly. We can count on a double-probe system and microprocessor control, further managed by the exclusive P.I.D. system.
Drying is the important final phase of the sterilization cycle. Perfect drying ensures the sterile maintenance of the instruments. Tecno-Gaz adopts a combined vacuum + heat system that ensures perfect drying of the sterilized materials, both unwrapped and wrapped.

The importance of vacuum

Why vacuum
After finishing loading the autoclave and closing the door, ambient air is trapped inside the chamber, which, due to different physical elasticity, does not mix with the steam produced. These "air pockets" remain "cold," therefore they are an impediment to the correct and safe sterilization of the treated materials. It is important to adopt a forced expulsion system for these air pockets.

Vacuum systems
There are several vacuum systems applicable to autoclaves. The most advanced and safe vacuum method to achieve safe sterilization on all materials, including hollow and porous ones, is the fractionated vacuum.

Fractionated vacuum
Europa B Evo – Europa B Evo 24 adopt the fractionated vacuum system. The fractionated vacuum is a system that alternates phases of negative pressure with phases of positive pressure and is implemented at the start of each sterilization cycle. This method is the ultimate technical expression of vacuum and ensures the expulsion of air pockets in all materials, even in hollow and porous ones.

Cycles

Fixed temperatures
The temperatures set on our autoclave cycles are 134°C and 121°C. The 134°C cycles are normally used for the sterilization of solid and ferrous materials. The 121°C cycles are used for thermoplastics, fabrics, and sensitive materials. Always sterilize materials by following the indications provided by the device manufacturer.

Simplicity of use
Choosing and selecting a sterilization cycle on Tecno-Gaz autoclaves is very simple and intuitive. One key allows you to scroll and view data relating to each cycle on the large display, allowing you to identify the most suitable cycle; then, it is sufficient to press one button to automatically start the entire sterilization cycle without having to worry about anything else. For any error or alarm, messages and LED indicators will call your attention.

Completely automatic cycles
All cycles are completely automatic; all phases are managed by an advanced board complete with a powerful microprocessor. Every phase (vacuum, preheating, exposure time, drying) is monitored, supported, and managed automatically. There is no human involvement in the execution of the cycles.

Wide range of operating cycles
Europa B Evo and Europa B Evo 24 autoclaves are equipped with:
1 sterilization cycle at 134°C for unwrapped and wrapped materials.
1 sterilization cycle at 121°C for unwrapped and wrapped materials.
1 flash sterilization cycle for rapid cycles.
1 specific prion sterilization cycle for C&J disease.

Operator-free cycles with automatic shutdown
All sterilization cycles have an automatic function that, in the absence of an operator at the end of the cycle, starts an anti-condensation phase and an automatic shutdown. This system saves energy and keeps the equipment safe.

Test cycles
Our autoclaves come complete with test cycles for periodic control of the equipment using physical and functional systems.
Helix test to evaluate vacuum capability in porous bodies.
Bowie & Dick test to evaluate vacuum capability in bodies.
Vacuum test to evaluate the vacuum maintenance capability.

Safety for operators

Door safety
We have applied three safety devices to the door:
The first is mechanical-electromagnetic: it activates the moment the sterilization cycle is started and completely blocks the door from opening. This device can be released at the end of the cycle by activating a specific button, and only when positive pressure is close to zero.
The second is electrical: it activates automatically the moment there is a clear attempt at forced opening of the machine.
The third is dynamic: the gasket is made with a new concept that does not allow the door to open in case of pressure inside the chamber.

Applied safety features
Certified safety valve.
PED on sterilization chambers.
Chamber insulation with certified ceramic material.

Flexible autoclaves

For a leading company like ours, the first objective is to create "flexible" devices that can be adapted to the individual needs of operators to allow for operational ease and savings in time and money. During the project development phase, it becomes a priority for our technicians to study technical solutions that can guarantee this all-important feature. The Europa B Evo – Europa B Evo 24 autoclaves can count on a series of solutions that allow the operator to set up the autoclave according to their own operational needs.

Water tank filling: prepare your autoclaves according to your needs
You can choose how to set up your autoclave.
Europa B Evo is already ready to:
Have autonomous operation, using the water from the internal tanks and manually loading/unloading pure and used water.
Be connected directly to the water mains, via a specific reverse osmosis system (mod. Pura), to have a continuous water supply and automatic drainage, without wasting time on manual operations.


Advice
For those who use the autoclave constantly and do not want the implications related to purchasing distilled water and managing tank filling and drainage, we recommend adopting the Pura system; you will save time and money and protect the autoclave because you will always have controlled and suitable water.

Internal machine tanks
All autoclaves have a pure water tank and a used water tank inside the unit. Each tank is equipped with sensors to signal minimum and maximum levels.

Filling the tanks
If the autoclave is connected to the mod. Pura device, the tanks fill automatically, whereas if you intend to use it autonomously, water filling is done manually. Tecno-Gaz autoclaves, to facilitate this operation, are equipped with a filling method using a pump and a full-tank detection system that stops the water flow. This important option, standard on all models in the line, avoids human error due to overfilling and reduces operator effort. The autoclave is also set up for manual tank filling in case the fill pump does not work.

Chamber and load
All Tecno-Gaz autoclave chambers are built with special stainless steel. They are produced using advanced industrial systems and subjected to strict control and individual testing procedures.

Load and dimensions
A parameter of great interest to buyers is the chamber volume, as it is used as the sole parameter to evaluate how much load the autoclave can sterilize.
In truth, we can find autoclaves with larger chambers than others, but with the capacity to sterilize a smaller amount of load. All this is determined by technical choices: heating system, heating element power, etc...
Always evaluate carefully not only the volume of the chamber but also and above all the load quantity declared by the manufacturers, which is normally around 750/1,000 g per tray.

Rich standard equipment
We believe that every autoclave should be supplied with all the equipment needed to perform normal daily operations and those accessories needed for the management and control of the equipment itself. Therefore, Tecno-Gaz autoclaves are offered already complete with all possible accessories and preparations.
Integrated printer on all models: ensures the recording of sterilization cycles and allows for the formalization of the vacuum test.
Preparation for water mains connection: all autoclaves are prepared for water mains connection via Pura.
Included accessories: 1 closed tray holder, 4 aluminum tray holders, 1 dual-function key for tray extraction and door adjustment, water filling and drainage hoses, sponge for chamber cleaning.

Technical Characteristics:
Power supply: 230V-50/60 Hz
External dimensions (mm): 510x590x390
Tray dimensions (W x H x D) (mm): 184 x 17 x 286
Weight (kg): 54
Absorption: 1,700 W
Chamber dimensions (mm): Ø 245x320
Thermal printer

Included:
1 closed tray holder
4 aluminum trays
1 dual-use key for extracting trays and adjusting the door
1 water filling and drainage hose and sponge for cleaning

Codice CFS: ST0001534

Marca: Tecno-gaz

Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.

LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).

In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.

In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.

Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:

  • Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
  • Di uguale qualità rispetto ad un campione o modello analogo
  • Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
  • Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore

Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.

Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.

Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:

  • non comprendenti imballi, accessori e manualistiche originali.
  • ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
  • la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.

Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.

Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.

Sede Centrale (indirizzo geografico presentazione reclami):

CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608

P.IVA: 01883060491 - CCIAA e REA: 205156

Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30

→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica

In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.


Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.

Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.

Termine per l'esercizio del diritto di recesso

Il periodo di recesso scade dopo 14 giorni:

  • dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
  • nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.

Modalità di esercizio del diritto di recesso

Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.

La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.

Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.

Restituzione dei prodotti

Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.

Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.

La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.

Stato dei prodotti restituiti

Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.

Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.

La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.

Rimborso

In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.

Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.

CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.

Esclusioni dal diritto di recesso

Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:

  • ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
  • ai beni confezionati su misura o chiaramente personalizzati;
  • agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.

Foro competente

Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.

Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta