Europa B Evo 24 is a next-generation autoclave with several new features in terms of design and operational efficiency, developed in collaboration between the Tecno-Gaz research department and other major external development organizations.
Europa B Evo 24 is indispensable in all medical and dental facilities and in all sectors where safe sterilization is required for all materials:
hollow, porous, solid, unwrapped and wrapped.
Europa B Evo 24 continues the success that Tecno-Gaz has enjoyed for years; in fact, thousands of professionals use Tecno-Gaz autoclaves with great satisfaction.
Safety features applied
- Certified safety valve.
- PED on sterilization chambers.
- Chamber insulation with certified ceramic material
The new control panel with a blue display has a strong aesthetic impact and great modernity.
The new charging connections that fit flush with the front of the autoclave represent a true innovation.
The study of operator needs and legal requirements led the Research & Development department of Tecno-Gaz S.p.A. to create a biological incubator managed directly by the autoclave in an autonomous manner, which functions even when the autoclave is turned off.
Biological tests are the basis for evaluating the validity of the autoclave according to current regulations; therefore, Tecno-Gaz S.p.A. has taken another great step towards the future
Europa B Evo features
- Circular chamber in treated AISI 304 stainless steel
- Maximum load per cycle 8 kg
- 3 safety devices on the door: electromagnetic, electrical, dynamic
- Control board integrated into the dashboard
- Graphic display
- Automatic baric alignment system
- Water loading with pump system and automatic full tank block
- Door gasket to ensure maximum durability
- Rear dashboard predisposition, with the possibility of automatic water loading and unloading
- Forced ventilation system integrated into the equipment
- Protected tray holder that prevents contact between the load and the chamber
The P.I.D. system
The primary commitment of a company like Tecno-Gaz is to create a product with unique solutions, characteristics, and features that ensure maximum reliability and safety for the user.
Our research offices, with the support and collaboration of external bodies, have created an extraordinary system that has been applied for the first time to our autoclaves; this innovative device is the P.I.D.
P.I.D. is an acronym for Proportional-Integral-Derivative and is the ultimate expression of closed-loop controls.
The structure of this sophisticated control is simple and flexible.
P.I.D. ensures constant control and monitoring of the entire functional system of the autoclave, intervening automatically in the event of anomalies in technical and electronic parameters.
A device that behaves like "a real technician" with real-time diagnostic and intervention capabilities.
A solution that limits anomalies and alarms, guaranteeing maximum reliability and minimizing any machine downtime.
Sterilization
Autoclaves capable of sterilizing type B loads
There are many models of autoclaves, with different features and characteristics.
Every medical facility or practice must adopt the model most suitable for its operational needs, dictated by the loads it must sterilize.
Regarding loads, EN 13060 precisely defined the classification, clarifying that type B loads refer to the following materials:
Porous bodies:
Porous bodies are simple or composite materials that can absorb fluids (fabrics, gowns, gauze, dressings, etc.)
Hollow bodies:
Hollow bodies are materials or devices with cavities, obstructions, etc.
These are divided into two classes defined precisely through an accurate description of the ratio between length and diameter.
We provide some general reference concepts below.
Type B: cannulas, tubes, or devices with significant passages
Type A: turbines, handpieces, and devices with blind holes or small dimensions.
Given this, it is evident that in all facilities where such materials are used, they must opt for a state-of-the-art autoclave capable of guaranteeing safe sterilization of type B loads.
Tecno-Gaz spa produces a vast range of autoclaves that can ensure correct sterilization of all types of materials, particularly type B loads:
Europa B Evo 24, the autoclave with a fractional vacuum system, complete with various devices.
Autoclaves that guarantee safe sterilization
Constantly monitored cycles.
The Europa B Evo – Europa B Evo 24 autoclave line is complete with a device for constant control and monitoring of sterilization cycles.
Any type of anomaly is detected, and if it jeopardizes the sterilization cycle, the equipment is immediately blocked and the anomaly is displayed via a message.
Non-manipulable preset cycles.
All cycles are preset and always guarantee safe sterilization of the treated materials.
There is no possibility of intervention or manipulation of the cycles by operators, which avoids any type of possible human error.
All cycles ensure the sterilization of type B loads.
All sterilization cycles have the fractional vacuum system, controls, and parameters that ensure the sterilization of type B loads. Even an incorrect selection of the desired cycle always ensures safe sterilization for any type of material treated.
Ergonomics and ease of use
Just press a button to select the cycle and another button to start the complete process.
It is impossible to make a mistake, impossible to select a cycle that does not ensure correct sterilization; any operational error is signaled via error messages.
The autoclave can be used by multiple people without the possibility of causing damage or problems.
In this important aspect too, Tecno-Gaz wanted to provide maximum operational safety.
The sterilization process
The sterilization process is composed of different phases; for each point, Tecno-Gaz has adopted cutting-edge technical solutions.
Vacuum is the first phase of the cycle and is decisive for correct sterilization. We ensure an excellent result by adopting a very high-quality pump, which allows the removal of air pockets even in hollow and porous bodies.
Preheating is the phase in which the sterilization cycle parameters, temperature, and pressure are stabilized.
We adopt a preheating system with a heating element designed to reduce the times of this phase to a minimum.
Exposure time is the period during which all microorganisms are eradicated; pressure, temperature, and time must be monitored perfectly.
We can count on a dual-probe system and microprocessor control, further managed by the exclusive P.I.D. system.
Drying is the important final phase of the sterilization cycle.
Perfect drying ensures the sterile maintenance of the instruments.
Tecno-Gaz adopts a combined vacuum + heat system that ensures perfect drying of the sterilized materials, both loose and wrapped.
The importance of vacuum
Why vacuum?
After finishing loading the autoclave and closing the door, ambient air is trapped inside the chamber, which, due to different physical elasticity, does not mix with the steam produced.
These "air bubbles" remain "cold"; therefore, they are an impediment to a correct and safe sterilization of the treated materials.
It is important to adopt a system of forced expulsion of these air bubbles.
Vacuum systems
There are different vacuum systems applicable to autoclaves.
The most advanced and safe vacuum method for obtaining safe sterilization on all materials, including hollow and porous ones, is fractional vacuum.
Fractional vacuum
Europa B Evo – Europa B Evo 24 adopt the fractional vacuum system.
Fractional vacuum is a system that alternates phases of negative pressure with phases of positive pressure and is implemented at the beginning of each sterilization cycle.
This method is the highest technical expression of vacuum and ensures the expulsion of air pockets in all materials, even in hollow and porous ones.
Cycles
Preset temperatures
The temperatures set on the cycles of our autoclaves are 134°C and 121°C.
134°C cycles are normally used for the sterilization of solid and ferrous materials.
121°C cycles are used for thermoplastics, fabrics, and sensitive materials.
Always sterilize materials following the instructions given by the device manufacturer.
Simplicity of use
Choosing and selecting a sterilization cycle on Tecno-Gaz autoclaves is very simple and intuitive.
A key allows you to scroll and view on the large display the data relating to each cycle, allowing you to identify the most suitable cycle; then it is sufficient to press a button to automatically start the entire sterilization cycle, without having to worry about anything else.
For any error or alarm, messages and LED signals will call your attention.
Fully automatic cycles
All cycles are fully automatic; all phases are managed by the advanced board complete with a powerful microprocessor.
Every phase (vacuum, preheating, exposure time, drying) is monitored, supported, and managed automatically. There is no human involvement in the execution of the cycles.
Wide choice of operational cycles
The Europa B Evo and Europa B Evo 24 autoclaves are equipped with:
1 sterilization cycle at 134°C for loose and wrapped materials.
1 sterilization cycle at 121°C for loose and wrapped materials.
1 flash sterilization cycle for rapid cycles.
1 prion sterilization cycle specific for CJD disease.
Unattended cycles with auto-shutdown
All sterilization cycles have an automatic function that, in the absence of an operator at the end of the cycle, starts an anti-condensation phase and automatic shutdown.
This system saves energy and keeps the equipment safe.
Test cycles
Our autoclaves are complete with test cycles for periodic control of the equipment, using physical and functional systems.
Helix test to evaluate vacuum capacity in porous bodies.
Bowie & Dick test to evaluate vacuum capacity in bodies.
Vacuum test to evaluate vacuum maintenance capacity.
Safety for operators
Door safety
We have applied three safety devices to the door:
The first is mechanical-electromagnetic: it is activated the moment the sterilization cycle begins and completely blocks the door from opening. This device can be released at the end of the cycle by activating a specific button and only with positive pressure close to zero.
The second is electrical: it is activated automatically the moment there is a clear attempt at forced opening of the machine.
The third is dynamic: the gasket is made with a new concept, which does not allow the door to be opened in the event of pressure inside the chamber.
Safety features applied
Certified safety valve.
PED on sterilization chambers.
Chamber insulation with certified ceramic material.
Flexible autoclaves
For a leading company like ours, the first objective is to create "flexible" devices that can be adapted to the individual needs of operators, to allow them operational ease, and savings in time and money. During the project development phase, it becomes a priority for our technicians to study technical solutions that can guarantee this all-important feature. The Europa B Evo – Europa B Evo 24 autoclaves can count on a series of solutions that allow the operator to be able to set the autoclave according to their own operational needs.
Water tank filling: set up the autoclaves according to your needs
You can choose how to set up your autoclave.
Europa B Evo is already ready for:
Autonomous operation, using water from internal tanks and performing manual loading and unloading of pure and used water.
They can be connected directly to the water mains via a special reverse osmosis system mod. Pura, and thus have a continuous supply of water and automatic drainage, without wasting time on manual operations.
Advice
For those who constantly use the autoclave and do not want to deal with the purchase of distilled water and the management of filling and emptying tanks, we recommend the adoption of the Pura system; you will thus save time, money, and protect the autoclave because you will always have controlled and suitable water.
Internal machine tanks
All autoclaves have a pure water tank and a used water tank inside the autoclave.
Each tank is equipped with probes for signaling minimum and maximum levels.
Tank filling
If the autoclave is connected to the mod. Pura device, filling the tanks is automatic, while if you intend to use it autonomously, water loading is done manually.
Tecno-Gaz autoclaves, to facilitate this operation, are equipped with a loading method with a pump and a full tank detection system, which interrupts water loading.
This important option, standard on all models in the line, avoids human errors due to excessive pouring and reduces operator effort.
The autoclave is also designed for manual tank filling, in case the loading pump does not work.
Chamber and load
All chambers of Tecno-Gaz autoclaves are built with special stainless steel.
They are produced with advanced industrial systems, subjected to strict control and individual testing procedures.
Load and dimensions
A parameter of great interest to buyers is the volume of the chamber, as it is used as the sole parameter to evaluate how much load the autoclave can sterilize.
In truth, we can find autoclaves with larger chambers than others, but with the ability to sterilize a smaller amount of load.
All this is determined by technical choices: heating system, heating element power, etc.
Always evaluate carefully, not only the chamber volume but also and above all the amount of load declared by the manufacturers, which is normally around 750/1,000 grams per tray.
Rich standard equipment
We believe that every autoclave should be supplied with all the equipment needed to comply with normal daily operations and those accessories used for the management and control of the equipment itself.
Thus, Tecno-Gaz autoclaves are offered already complete with all possible accessories and predispositions.
Integrated printer on all models: ensures the registration of sterilization cycles and allows the vacuum test to be formalized.
Predisposition for water mains connection: all autoclaves have a predisposition for water mains connection via Pura.
Technical features:
Power supply: 230V-50/60 Hz
External dimensions mm: 510x390x730
Weight kg: 58
Power consumption: 2,200 W
Chamber dimensions mm: Ø 245x500
Included:
4 Aluminum trays
1 Closed tray holder
1 Dual-use key to extract the trays and adjust the door
1 Cleaning sponge and integrated osmosis system
1 User manual
Water loading and unloading tubes
Codice CFS: ST12366
Marca: Tecno-gaz
Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.
LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).
In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.
Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:
- Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
- Di uguale qualità rispetto ad un campione o modello analogo
- Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
- Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore
Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.
Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.
Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:
- non comprendenti imballi, accessori e manualistiche originali.
- ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
- la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.
Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.
Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.
Sede Centrale (indirizzo geografico presentazione reclami):
CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608
P.IVA: 01883060491 - CCIAA e REA: 205156
Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30
→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica
In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.
Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.
Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.
Termine per l'esercizio del diritto di recesso
Il periodo di recesso scade dopo 14 giorni:
- dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
- nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.
Modalità di esercizio del diritto di recesso
Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.
La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.
Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.
Restituzione dei prodotti
Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.
Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.
La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.
Stato dei prodotti restituiti
Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.
Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.
La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.
Rimborso
In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.
Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.
CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.
Esclusioni dal diritto di recesso
Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:
- ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
- ai beni confezionati su misura o chiaramente personalizzati;
- agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.
Foro competente
Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.
Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta
Brand: Tecno-gaz
Tecno Gaz Europa B EVO 24 Autoclave - Class B 24 L
+ Special 24-month warranty and online course on sterilization and free delivery of operational protocols
(IVA esclusa)
(IVA esclusa)
€4409,08 (IVA 22% inclusa)
Ordinabile - Spedizione in 15 giorni
Europa B Evo 24 is a next-generation autoclave with several new features in terms of design and operational efficiency, developed in collaboration between the Tecno-Gaz research department and other major external development organizations.
Europa B Evo 24 is indispensable in all medical and dental facilities and in all sectors where safe sterilization is required for all materials:
hollow, porous, solid, unwrapped and wrapped.
Europa B Evo 24 continues the success that Tecno-Gaz has enjoyed for years; in fact, thousands of professionals use Tecno-Gaz autoclaves with great satisfaction.
Safety features applied
- Certified safety valve.
- PED on sterilization chambers.
- Chamber insulation with certified ceramic material
The new control panel with a blue display has a strong aesthetic impact and great modernity.
The new charging connections that fit flush with the front of the autoclave represent a true innovation.
The study of operator needs and legal requirements led the Research & Development department of Tecno-Gaz S.p.A. to create a biological incubator managed directly by the autoclave in an autonomous manner, which functions even when the autoclave is turned off.
Biological tests are the basis for evaluating the validity of the autoclave according to current regulations; therefore, Tecno-Gaz S.p.A. has taken another great step towards the future
Europa B Evo features
- Circular chamber in treated AISI 304 stainless steel
- Maximum load per cycle 8 kg
- 3 safety devices on the door: electromagnetic, electrical, dynamic
- Control board integrated into the dashboard
- Graphic display
- Automatic baric alignment system
- Water loading with pump system and automatic full tank block
- Door gasket to ensure maximum durability
- Rear dashboard predisposition, with the possibility of automatic water loading and unloading
- Forced ventilation system integrated into the equipment
- Protected tray holder that prevents contact between the load and the chamber
The P.I.D. system
The primary commitment of a company like Tecno-Gaz is to create a product with unique solutions, characteristics, and features that ensure maximum reliability and safety for the user.
Our research offices, with the support and collaboration of external bodies, have created an extraordinary system that has been applied for the first time to our autoclaves; this innovative device is the P.I.D.
P.I.D. is an acronym for Proportional-Integral-Derivative and is the ultimate expression of closed-loop controls.
The structure of this sophisticated control is simple and flexible.
P.I.D. ensures constant control and monitoring of the entire functional system of the autoclave, intervening automatically in the event of anomalies in technical and electronic parameters.
A device that behaves like "a real technician" with real-time diagnostic and intervention capabilities.
A solution that limits anomalies and alarms, guaranteeing maximum reliability and minimizing any machine downtime.
Sterilization
Autoclaves capable of sterilizing type B loads
There are many models of autoclaves, with different features and characteristics.
Every medical facility or practice must adopt the model most suitable for its operational needs, dictated by the loads it must sterilize.
Regarding loads, EN 13060 precisely defined the classification, clarifying that type B loads refer to the following materials:
Porous bodies:
Porous bodies are simple or composite materials that can absorb fluids (fabrics, gowns, gauze, dressings, etc.)
Hollow bodies:
Hollow bodies are materials or devices with cavities, obstructions, etc.
These are divided into two classes defined precisely through an accurate description of the ratio between length and diameter.
We provide some general reference concepts below.
Type B: cannulas, tubes, or devices with significant passages
Type A: turbines, handpieces, and devices with blind holes or small dimensions.
Given this, it is evident that in all facilities where such materials are used, they must opt for a state-of-the-art autoclave capable of guaranteeing safe sterilization of type B loads.
Tecno-Gaz spa produces a vast range of autoclaves that can ensure correct sterilization of all types of materials, particularly type B loads:
Europa B Evo 24, the autoclave with a fractional vacuum system, complete with various devices.
Autoclaves that guarantee safe sterilization
Constantly monitored cycles.
The Europa B Evo – Europa B Evo 24 autoclave line is complete with a device for constant control and monitoring of sterilization cycles.
Any type of anomaly is detected, and if it jeopardizes the sterilization cycle, the equipment is immediately blocked and the anomaly is displayed via a message.
Non-manipulable preset cycles.
All cycles are preset and always guarantee safe sterilization of the treated materials.
There is no possibility of intervention or manipulation of the cycles by operators, which avoids any type of possible human error.
All cycles ensure the sterilization of type B loads.
All sterilization cycles have the fractional vacuum system, controls, and parameters that ensure the sterilization of type B loads. Even an incorrect selection of the desired cycle always ensures safe sterilization for any type of material treated.
Ergonomics and ease of use
Just press a button to select the cycle and another button to start the complete process.
It is impossible to make a mistake, impossible to select a cycle that does not ensure correct sterilization; any operational error is signaled via error messages.
The autoclave can be used by multiple people without the possibility of causing damage or problems.
In this important aspect too, Tecno-Gaz wanted to provide maximum operational safety.
The sterilization process
The sterilization process is composed of different phases; for each point, Tecno-Gaz has adopted cutting-edge technical solutions.
Vacuum is the first phase of the cycle and is decisive for correct sterilization. We ensure an excellent result by adopting a very high-quality pump, which allows the removal of air pockets even in hollow and porous bodies.
Preheating is the phase in which the sterilization cycle parameters, temperature, and pressure are stabilized.
We adopt a preheating system with a heating element designed to reduce the times of this phase to a minimum.
Exposure time is the period during which all microorganisms are eradicated; pressure, temperature, and time must be monitored perfectly.
We can count on a dual-probe system and microprocessor control, further managed by the exclusive P.I.D. system.
Drying is the important final phase of the sterilization cycle.
Perfect drying ensures the sterile maintenance of the instruments.
Tecno-Gaz adopts a combined vacuum + heat system that ensures perfect drying of the sterilized materials, both loose and wrapped.
The importance of vacuum
Why vacuum?
After finishing loading the autoclave and closing the door, ambient air is trapped inside the chamber, which, due to different physical elasticity, does not mix with the steam produced.
These "air bubbles" remain "cold"; therefore, they are an impediment to a correct and safe sterilization of the treated materials.
It is important to adopt a system of forced expulsion of these air bubbles.
Vacuum systems
There are different vacuum systems applicable to autoclaves.
The most advanced and safe vacuum method for obtaining safe sterilization on all materials, including hollow and porous ones, is fractional vacuum.
Fractional vacuum
Europa B Evo – Europa B Evo 24 adopt the fractional vacuum system.
Fractional vacuum is a system that alternates phases of negative pressure with phases of positive pressure and is implemented at the beginning of each sterilization cycle.
This method is the highest technical expression of vacuum and ensures the expulsion of air pockets in all materials, even in hollow and porous ones.
Cycles
Preset temperatures
The temperatures set on the cycles of our autoclaves are 134°C and 121°C.
134°C cycles are normally used for the sterilization of solid and ferrous materials.
121°C cycles are used for thermoplastics, fabrics, and sensitive materials.
Always sterilize materials following the instructions given by the device manufacturer.
Simplicity of use
Choosing and selecting a sterilization cycle on Tecno-Gaz autoclaves is very simple and intuitive.
A key allows you to scroll and view on the large display the data relating to each cycle, allowing you to identify the most suitable cycle; then it is sufficient to press a button to automatically start the entire sterilization cycle, without having to worry about anything else.
For any error or alarm, messages and LED signals will call your attention.
Fully automatic cycles
All cycles are fully automatic; all phases are managed by the advanced board complete with a powerful microprocessor.
Every phase (vacuum, preheating, exposure time, drying) is monitored, supported, and managed automatically. There is no human involvement in the execution of the cycles.
Wide choice of operational cycles
The Europa B Evo and Europa B Evo 24 autoclaves are equipped with:
1 sterilization cycle at 134°C for loose and wrapped materials.
1 sterilization cycle at 121°C for loose and wrapped materials.
1 flash sterilization cycle for rapid cycles.
1 prion sterilization cycle specific for CJD disease.
Unattended cycles with auto-shutdown
All sterilization cycles have an automatic function that, in the absence of an operator at the end of the cycle, starts an anti-condensation phase and automatic shutdown.
This system saves energy and keeps the equipment safe.
Test cycles
Our autoclaves are complete with test cycles for periodic control of the equipment, using physical and functional systems.
Helix test to evaluate vacuum capacity in porous bodies.
Bowie & Dick test to evaluate vacuum capacity in bodies.
Vacuum test to evaluate vacuum maintenance capacity.
Safety for operators
Door safety
We have applied three safety devices to the door:
The first is mechanical-electromagnetic: it is activated the moment the sterilization cycle begins and completely blocks the door from opening. This device can be released at the end of the cycle by activating a specific button and only with positive pressure close to zero.
The second is electrical: it is activated automatically the moment there is a clear attempt at forced opening of the machine.
The third is dynamic: the gasket is made with a new concept, which does not allow the door to be opened in the event of pressure inside the chamber.
Safety features applied
Certified safety valve.
PED on sterilization chambers.
Chamber insulation with certified ceramic material.
Flexible autoclaves
For a leading company like ours, the first objective is to create "flexible" devices that can be adapted to the individual needs of operators, to allow them operational ease, and savings in time and money. During the project development phase, it becomes a priority for our technicians to study technical solutions that can guarantee this all-important feature. The Europa B Evo – Europa B Evo 24 autoclaves can count on a series of solutions that allow the operator to be able to set the autoclave according to their own operational needs.
Water tank filling: set up the autoclaves according to your needs
You can choose how to set up your autoclave.
Europa B Evo is already ready for:
Autonomous operation, using water from internal tanks and performing manual loading and unloading of pure and used water.
They can be connected directly to the water mains via a special reverse osmosis system mod. Pura, and thus have a continuous supply of water and automatic drainage, without wasting time on manual operations.
Advice
For those who constantly use the autoclave and do not want to deal with the purchase of distilled water and the management of filling and emptying tanks, we recommend the adoption of the Pura system; you will thus save time, money, and protect the autoclave because you will always have controlled and suitable water.
Internal machine tanks
All autoclaves have a pure water tank and a used water tank inside the autoclave.
Each tank is equipped with probes for signaling minimum and maximum levels.
Tank filling
If the autoclave is connected to the mod. Pura device, filling the tanks is automatic, while if you intend to use it autonomously, water loading is done manually.
Tecno-Gaz autoclaves, to facilitate this operation, are equipped with a loading method with a pump and a full tank detection system, which interrupts water loading.
This important option, standard on all models in the line, avoids human errors due to excessive pouring and reduces operator effort.
The autoclave is also designed for manual tank filling, in case the loading pump does not work.
Chamber and load
All chambers of Tecno-Gaz autoclaves are built with special stainless steel.
They are produced with advanced industrial systems, subjected to strict control and individual testing procedures.
Load and dimensions
A parameter of great interest to buyers is the volume of the chamber, as it is used as the sole parameter to evaluate how much load the autoclave can sterilize.
In truth, we can find autoclaves with larger chambers than others, but with the ability to sterilize a smaller amount of load.
All this is determined by technical choices: heating system, heating element power, etc.
Always evaluate carefully, not only the chamber volume but also and above all the amount of load declared by the manufacturers, which is normally around 750/1,000 grams per tray.
Rich standard equipment
We believe that every autoclave should be supplied with all the equipment needed to comply with normal daily operations and those accessories used for the management and control of the equipment itself.
Thus, Tecno-Gaz autoclaves are offered already complete with all possible accessories and predispositions.
Integrated printer on all models: ensures the registration of sterilization cycles and allows the vacuum test to be formalized.
Predisposition for water mains connection: all autoclaves have a predisposition for water mains connection via Pura.
Technical features:
Power supply: 230V-50/60 Hz
External dimensions mm: 510x390x730
Weight kg: 58
Power consumption: 2,200 W
Chamber dimensions mm: Ø 245x500
Included:
4 Aluminum trays
1 Closed tray holder
1 Dual-use key to extract the trays and adjust the door
1 Cleaning sponge and integrated osmosis system
1 User manual
Water loading and unloading tubes
Codice CFS: ST12366
Marca: Tecno-gaz
Assistenza & Garanzia fornita direttamente da CFS Prodotti Medicali S.r.l.
LA GARANZIA LEGALE:
La garanzia di 24 mesi ai sensi del DL 24/02 si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
Tale garanzia è riservata al Consumatore privato (persona fisica che acquista la merce per scopi non riferibili alla propria attività professionale, ovvero effettua l'acquisto senza indicare nel modulo d'ordine un riferimento di Partita IVA).
In caso di acquisto con riferimento di Partita IVA (scopi riferibili ad attività professionali) la garanzia è di 12 mesi, e si applica al prodotto che presenti un difetto di conformità, purché il prodotto stesso sia stato utilizzato correttamente, nel rispetto della sua destinazione d'uso e di quanto previsto nella documentazione tecnica allegata.
In caso di difetto di conformità CFS Prodotti Medicali S.r.l. provvede al ripristino della conformità del prodotto mediante riparazione/sostituzione.
Cos'è il difetto di conformità?
Vi è un difetto di Conformità quando il bene acquistato, sempre entro 24 Mesi dalla data di consegna, non è o non è più:
- Idoneo all'uso al quale servono abitualmente beni dello stesso tipo
- Di uguale qualità rispetto ad un campione o modello analogo
- Di uguale qualità rispetto a prestazioni abituali di un bene dello stesso tipo anche tenuto conto della natura del bene e/o della sua pubblicità
- Idoneo all'uso particolare voluto dal Consumatore e dichiarato dal venditore
Il cliente dovrà far pervenire il bene presso la sede di CFS Prodotti Medicali S.r.l. in Via G.B. Guarini 58 - Livorno (LI).
Nel caso in cui per qualsiasi ragione, non fosse in grado di rendere al proprio cliente un prodotto in garanzia (ripristinato o sostituito), CFS Prodotti Medicali S.r.l. potrà procedere a propria discrezione alla restituzione dell'intero importo pagato oppure alla sostituzione con un prodotto con caratteristiche pari o superiori.
Attenzione! Le spese di spedizione verso e da CFS Prodotti Medicali S.r.l. sono a carico del Cliente.
Saranno respinte al Mittente, con spese a suo carico, tutte le spedizioni di prodotti:
- non comprendenti imballi, accessori e manualistiche originali.
- ricevuti con imballo esterno non idoneo o inadeguato e quindi danneggiati durante il trasporto.
- la Garanzia non copre i danni dovuti al non utilizzo degli imballi originali e di adeguato imballo protettivo esterno di sicurezza non autorizzati dal Centro assistenza.
Attenzione! La Garanzia del prodotto rimane del tutto invariata con decorrenza dalla data di acquisto.
Le riparazioni o le sostituzioni potranno avvenire anche con parti o prodotti ricondizionati che, pur non necessariamente uguali ai prodotti difettosi contenuti nella fornitura originale, siano comunque equivalenti o leggermente superiori a parti e prodotti nuovi per funzionalità, prestazioni ed estetica.
Se il prodotto risulta manomesso o le etichette che identificano il Serial o Part Number risultino rimosse o manomesse, CFS Prodotti Medicali S.r.l. si riserverà di giudicare la validità della Garanzia.
Convenzionalmente viene escluso ogni diritto del Cliente ad un risarcimento danni o indennizzi nonché ogni responsabilità contrattuale o extracontrattuale per danni diretti o indiretti a persone e/o cose.
Nel caso di modifiche alle Condizioni di Garanzia, CFS Prodotti Medicali S.r.l. applicherà le condizioni presenti sulla Garanzia per prodotti in vigore al momento dell'acquisto del Cliente.
Competenza: per ogni controversia è competente il Foro ai sensi di legge.
Sede Centrale (indirizzo geografico presentazione reclami):
CFS Prodotti Medicali S.r.l.
Via G.B. Guarini 58 - 57121 Livorno
Tel.: 0586/444369
Fax: 0586/443608
P.IVA: 01883060491 - CCIAA e REA: 205156
Orari Ufficio: Lunedì-Venerdì 8:30-12:30 13:30-17:30
→ Per attivare la Garanzia è necessario farne richiesta nell'apposita sezione del proprio account: Le mie richieste di Recesso - Garanzia - Assistenza Tecnica
In caso di contatto telefonico la nostra assistenza tecnica risponde da Lunedì a Venerdì dalle ore 9.00 alle ore 12.30.
Il prodotto verrà riparato oppure, nel caso in cui la riparazione non sia possibile, sostituito con uno uguale, equivalente o superiore secondo il giudizio di CFS Prodotti Medicali S.r.l..
In caso di difficoltà di reperimento del prodotto, CFS Prodotti Medicali S.r.l. ha facoltà di adempiere alle Condizioni di Garanzia mediante Nota di Credito e rimborso all'acquirente del corrente prezzo di mercato del prodotto stesso.
Ai sensi degli articoli 52 e seguenti del Codice del Consumo (D.Lgs. 206/2005), il consumatore ha il diritto di recedere dal contratto di acquisto senza fornire alcuna motivazione entro 14 giorni dalla consegna dei prodotti.
Per consumatore si intende la persona fisica che acquista per scopi estranei alla propria attività imprenditoriale, commerciale, artigianale o professionale.
Termine per l'esercizio del diritto di recesso
Il periodo di recesso scade dopo 14 giorni:
- dal giorno in cui il consumatore, o un terzo da lui designato diverso dal vettore, acquisisce il possesso fisico dei beni;
- nel caso di consegna di più beni ordinati con un solo ordine e consegnati separatamente, dal giorno in cui viene consegnato l'ultimo bene.
Modalità di esercizio del diritto di recesso
Per esercitare il diritto di recesso è possibile utilizzare l'apposito modulo online disponibile nell'area dedicata del sito.
La compilazione e l'invio del modulo costituiscono comunicazione esplicita della volontà di recedere dal contratto.
Una volta ricevuta la richiesta, CFS Prodotti Medicali S.r.l. invierà una conferma di ricezione all'indirizzo e-mail indicato dal cliente.
Restituzione dei prodotti
Dopo aver esercitato il diritto di recesso, il consumatore è tenuto a restituire i beni entro 14 giorni dalla comunicazione di recesso.
Le spese di restituzione dei beni sono a carico del consumatore, salvo diversa indicazione da parte di CFS Prodotti Medicali S.r.l.
La Sede Centrale di CFS Prodotti Medicali S.r.l. è in Via G.B. Guarini 58 - 57121 Livorno (LI). P.IVA: 01883060491.
Stato dei prodotti restituiti
Il consumatore può esaminare e testare il prodotto nella misura necessaria a verificarne natura, caratteristiche e funzionamento, come farebbe in un punto vendita fisico.
Il consumatore è responsabile dell'eventuale diminuzione del valore dei beni derivante da una manipolazione diversa da quella necessaria per stabilirne natura, caratteristiche e funzionamento.
La mancanza dell'imballo originale non comporta automaticamente la perdita del diritto di recesso, fermo restando l'obbligo di restituire il prodotto adeguatamente protetto per il trasporto.
Rimborso
In caso di esercizio del diritto di recesso, CFS Prodotti Medicali S.r.l. provvederà al rimborso di tutti i pagamenti ricevuti dal consumatore, inclusi gli eventuali costi di consegna standard sostenuti per l'acquisto.
Il rimborso sarà effettuato entro 14 giorni dalla ricezione della comunicazione di recesso utilizzando lo stesso mezzo di pagamento impiegato per la transazione iniziale, salvo diverso accordo con il consumatore.
CFS Prodotti Medicali S.r.l. potrà trattenere il rimborso fino al ricevimento dei beni oppure fino a quando il consumatore non abbia fornito prova dell'avvenuta spedizione degli stessi, se precedente.
Esclusioni dal diritto di recesso
Ai sensi dell'art. 59 del Codice del Consumo, il diritto di recesso non si applica, tra gli altri casi previsti dalla legge:
- ai prodotti sigillati che non si prestano ad essere restituiti per motivi igienici o connessi alla protezione della salute e che siano stati aperti dopo la consegna;
- ai beni confezionati su misura o chiaramente personalizzati;
- agli altri casi espressamente previsti dall'art. 59 del Codice del Consumo.
Foro competente
Per ogni controversia relativa all'interpretazione, esecuzione, validità o risoluzione del contratto, è competente il giudice del luogo di residenza o di domicilio del consumatore, purché situati nel territorio dello Stato italiano, ai sensi della normativa vigente.
Per ulteriori informazioni visita la sezione Contatti per inviare una richiesta
Tecno Gaz Europa B EVO 24 Autoclave - Class B 24 L


Articoli simili da considerare
Altri utenti hanno acquistato anche