{"title":"Tympanometers","description":"","products":[{"product_id":"impedenziometro-resonance-r16m-collegamento-pc-windows","title":"RESONANCE r16m Tympanometer - Windows PC connection","description":"\u003cp\u003e\u003cstrong\u003eThe r16m is an impedance meter that measures pressure and volume in the outer and middle ear.\u003c\/strong\u003e\u003cbr\u003eA probe inserted into the ear canal sends a tone to the patient, while an internal microphone detects the sound level. \u003cbr\u003eThe pressure created in the ear changes the stiffness of the tympanic membrane and the ossicular chain. \u003cbr\u003eBy monitoring volume variations in relation to pressure, pathologies can be diagnosed. \u003cbr\u003eThe use of the Impedance Meter is reserved for audiologists, personnel specializing in hearing care, or specialized technicians.\u003cbr\u003eThe device performs middle ear analysis at 226 Hz and 1 kHz, measuring both ipsilateral and contralateral acoustic reflexes.\u003c\/p\u003e\n\u003cp\u003eThe portable impedance meter can integrate the OAE module for otoacoustic emissions, the RE-VO2 video otoscope, and the portable Wi-Fi thermal printer.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAvailable tests\u003c\/strong\u003e\u003cbr\u003eImpedance audiometry\u003cbr\u003eReflexes\u003cbr\u003eQuick Test (sequence of impedance audiometry and reflex tests with editable protocols)\u003cbr\u003eHigh-frequency impedance audiometry (with pediatric mode)\u003cbr\u003eJerger Norm and Auto Classification\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eScreen\u003c\/strong\u003e\u003cbr\u003e7-inch TFT resistive touch screen\u003cbr\u003eResolution 800 x 480; 133 ppi 262K colors\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUser interface\u003c\/strong\u003e\u003cbr\u003eIntuitive icon-based system\u003cbr\u003eInternal patient data collection\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eReports\u003c\/strong\u003e\u003cbr\u003eData transfer to PC via Resonance Data Suite software\u003cbr\u003eReports with dedicated templates\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eData transfer to PC\u003c\/strong\u003e\u003cbr\u003eBluetooth 2.1\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eCommunication ports\u003c\/strong\u003e\u003cbr\u003e1 USB host type A (for software update via pen drive)\u003cbr\u003e1 Mini USB slave \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eWindows compatible software\u003c\/strong\u003e\u003cbr\u003eResonance MDS Management Data Suite \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSystem features\u003c\/strong\u003e\u003cbr\u003eOperating system: Microsoft® Windows® Embedded Compact\u003cbr\u003eCPU: TEGRA® 2 dual core @ 1 Ghz\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eTechnical specifications:\u003cbr\u003eDevice features\u003cbr\u003e\u003c\/strong\u003e180 L x 135 W x 41 H mm\u003cbr\u003eNet weight: 570 g\u003cbr\u003eMaterial: Self-extinguishing ABS UL 94 V0\u003cbr\u003ePower supply:\u003cbr\u003eBuilt-in 3.6 V, 3.1 Ah rechargeable lithium-ion battery\u003cbr\u003eExternal medical power supply: 100 - 240 Vac \/ 0.3 A - 50\/60 Hz (input); +5 Vdc \/ 2 A (output)\u003cbr\u003eBattery life (with rechargeable batteries):\u003cbr\u003eUp to 2 hours of continuous operation\u003cbr\u003eCharging time with external medical power supply: up to 80% in 2 hours \u003cbr\u003e\u003cstrong\u003eEnvironmental conditions\u003c\/strong\u003e\u003cbr\u003eStorage temperature: -20°C to +50°C\u003cbr\u003eOperating temperature: +15°C to +35°C\u003cbr\u003eHumidity: up to 90% (non-condensing)\u003cbr\u003ePressure: 700 hPa to 1060 hPa\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eImpedance audiometry:\u003cbr\u003eProbe tone frequency\u003c\/strong\u003e\u003cbr\u003e226 Hz, 85 dB SPL\u003cbr\u003e1000 Hz, 75 dB SPL with Admittance (Y), Susceptance (B), and Conductance (G) curves\u003cbr\u003eThe probe is designed for manual use\u003cbr\u003e\u003cstrong\u003eIntensity\u003c\/strong\u003e\u003cbr\u003e226 Hz: 85 dB SPL ± 2 dB\u003cbr\u003e1000 Hz: 75 dB SPL ± 2 dB\u003cbr\u003eFrequency accuracy: ± 0.5%\u003cbr\u003eTotal Harmonic Distortion (THD): \u0026lt; 1%\u003cbr\u003eMiddle ear analysis at 226 Hz and 1 kHz, measuring both ipsilateral and contralateral acoustic reflexes\u003cbr\u003e\u003cstrong\u003eAdmittance measurement\u003c\/strong\u003e\u003cbr\u003eMeasurement range at 226 Hz: 0.05 to 7 ml (compliance)\u003cbr\u003eDisplay scale: Automatic adjustment; available ranges at 226 Hz: 1, 2, 5, and 7 ml\u003cbr\u003eMeasurement range at 1000 Hz: 0 to +25 mmho\u003cbr\u003eDisplay scale: Automatic adjustment; available ranges at 1000 Hz: 5, 10, 15, 20, 25 mmho\u003cbr\u003e\u003cstrong\u003ePressure\u003c\/strong\u003e\u003cbr\u003eControl: Automatic\u003cbr\u003eExcursion: +100\/-200 or +200\/-400 daPa\u003cbr\u003ePressure accuracy: ± 10 daPa or ± 10%\u003cbr\u003eSweep speed: automatic or fast (200 daPa\/s)\u003cbr\u003eInstant display of measured value\u003cbr\u003eSafety limits: -750 to +550 daPa\u003cbr\u003e\u003cstrong\u003eAcoustic reflex test\u003c\/strong\u003e\u003cbr\u003eMode: manual and with automatic threshold search\u003cbr\u003eStimulus duration: 0.5 or 1 s\u003cbr\u003eUser-customizable protocols for all test methods\u003cbr\u003eIpsi or Contralateral stimulation for all reflex tests\u003cbr\u003eAutomatic peak search functions for the Quick Test\u003cbr\u003e\u003cstrong\u003eFrequency and intensity range\u003c\/strong\u003e\u003cbr\u003eIpsilateral:\u003cbr\u003ePure tone level: 50 to 100 dB HL\u003cbr\u003eFrequencies: 500, 1000, 2000, 4000 Hz\u003cbr\u003eFrequency accuracy: ± 1%\u003cbr\u003eTotal Harmonic Distortion (THD): \u0026lt; 3%\u003cbr\u003eContralateral:\u003cbr\u003ePure tone level: 50 to 110 dB HL\u003cbr\u003eFrequencies: 500, 1000, 2000, 4000 Hz\u003cbr\u003eFrequency accuracy: ± 1%\u003cbr\u003eCalibration accuracy: ± 3 dB\u003cbr\u003eLevel step: 5 or 10 dB\u003cbr\u003eOn\/Off ratio: \u0026gt; 70 dB\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eIncluded accessories:\u003c\/strong\u003e\u003cbr\u003e1 High-frequency probe\u003cbr\u003e1 Probe cleaning kit\u003cbr\u003e1 Insert\u003cbr\u003e1 Set of assorted tips; sizes from 6 mm to 15 mm\u003cbr\u003e1 Calibration cavity\u003cbr\u003e1 Resonance MDS software\u003cbr\u003e1 Medical power supply (100 Vac - 240 Vac)\u003cbr\u003e1 Carrying case\u003cbr\u003e1 Charging base\u003cbr\u003e1 USB Pen Drive (with multilingual quick start guide)\u003cbr\u003e1 Touch screen pen\u003c\/p\u003e","brand":"Resonance","offers":[{"title":"Default Title","offer_id":49812021772624,"sku":"DG14500","price":2465.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/3996\/8592\/files\/timpanometro_resonance_r16m_collegamento_pc_windows_2.png?v=1740040026"},{"product_id":"timpanometro-horentek-espirio-collegamento-pc-windows","title":"HORENTEK Espirio tympanometer - Windows PC connection","description":"\u003cp\u003e\u003cstrong\u003eESPIRIO is a tympanometer with Windows PC USB connectivity, offering automatic tympanometry, IPSI and CONTRA REFLEX, TONE DECAY, and ETF functionality.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e- Automatic Tympanometry\u003cbr\u003e- Automatic IPSI-lateral Acoustic Stapedial Reflex Search\u003cbr\u003e- Automatic CONTRA-lateral Acoustic Stapedial Reflex Search\u003cbr\u003e- Reflex Decay Test or Anderson Test\u003cbr\u003e- ETF Test or Eustachian Tube Function evaluation with intact tympanic membrane\u003cbr\u003e- ETF Test or Eustachian Tube Function evaluation with perforated tympanic membrane\u003c\/p\u003e\n\u003cp\u003eESPIRIO is an impedance meter manufactured by Horentek at its HQ in Livorno; Espirio is a clinical middle ear assessment instrument designed to evaluate its functionality. \u003cbr\u003eThe medical device is PC-based, portable, and reliable, featuring a high-precision mechanical pump capable of providing accurate results, as expected from an instrument of fine Italian craftsmanship. \u003cbr\u003eEspirio can perform various tests and print a detailed clinical report (PDF format) on the patient's parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePortability:\u003c\/strong\u003e ESPIRIO is lightweight, approximately 970 grams, requires standard mains power, and a USB connection to communicate with a Personal Computer (Windows) running the dedicated instrument software.\u003cbr\u003e\u003cstrong\u003eComputer Control:\u003c\/strong\u003e Connect ESPIRIO to a computer USB port, then connect the provided transformer to the power mains to use the device.\u003cbr\u003eYou can control ESPIRIO via the dedicated software developed by Horentek.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEspirio Software:\u003c\/strong\u003e\u003cbr\u003eEspirio SW is software developed by Horentek that allows for easy patient data management and has the capability to produce PDF reports ready for printing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePatient data:\u003c\/strong\u003e Complete patient database that allows for the printing of full clinical patient data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating mode: \u003c\/strong\u003ePC-Based with proprietary database\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable tests:\u003c\/strong\u003e\u003cbr\u003e- Automatic Tympanometry (from -600daPa to +300daPa)\u003cbr\u003e- Automatic IPSI-lateral stapedial reflex search, maximum stimulation 105dB HL at 500 Hz, 1kHz, 2kHz, and 4 kHz\u003cbr\u003e- Automatic CONTRA-lateral stapedial reflex search, maximum stimulation 105 dB HL at 500 Hz, 1 kHz, 2kHz, and 4kHz\u003cbr\u003e- Reflex Decay Test, Max Stimuli Intensity 105 dB HL\u003cbr\u003e- ETF with Intact Membrane: guided evaluation\u003cbr\u003e- ETF with Perforated Membrane: automatic evaluation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInterface:\u003c\/strong\u003e USB connection\u003cbr\u003e\u003cstrong\u003eMinimum PC requirements:\u003c\/strong\u003e\u003cbr\u003e- Processor: Intel® i5 equivalent or higher\u003cbr\u003e- RAM 4 GB\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScreen:\u003c\/strong\u003e\u003cbr\u003e- Resolution: 1280x720 (16:9) compatible with higher resolutions\u003cbr\u003e- Scale and layout: 100% dpi (recommended) *\u003cbr\u003e- Operating system: Windows 8 or later, 64-bit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003cbr\u003eDevice type: PC-controlled\u003cbr\u003eClass EN 60645-5\u003cbr\u003eVersion: ESPIRIO\u003cbr\u003eProbe Tone: 226 Hz\u003cbr\u003eProbe Tone Intensity: 85 dB SPL\u003cbr\u003eFrequency range: 500 Hz, 1 kHz, 2 kHz, and 4 kHz\u003cbr\u003eMaximum signal intensity: 105 dB HL\u003cbr\u003eAttenuator step: 5 dB HL\u003c\/p\u003e\n\u003cp\u003ePC connection: USB (with driver)\u003cbr\u003eControl software: ESPIRIO SW\u003cbr\u003eiPad connection: No\u003cbr\u003eDimensions: 21 x 16 x h 7 cm\u003cbr\u003eWeight: 970 g\u003cbr\u003ePower supply: 100-240 V, 50\/60 Hz\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupplied items:\u003c\/strong\u003e\u003cbr\u003e1 Headset with IPSI and CONTRA probe\u003cbr\u003e1 Power supply for electromedical devices\u003cbr\u003e1 Daily calibration cavity\u003cbr\u003e1 Assorted selection of ear tips\u003cbr\u003e1 USB connection cable\u003cbr\u003e1 Pen Drive with ESPIRIO SW installer\u003cbr\u003e1 Probe tip cleaning kit\u003cbr\u003e1 Spare Contra probe tip\u003cbr\u003e1 Pen Drive with User Manual (Soft Copy)\u003cbr\u003e1 Horentek branded carrying case\u003c\/p\u003e","brand":"Horentek","offers":[{"title":"Default Title","offer_id":49814608642384,"sku":"DG11556","price":2100.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/3996\/8592\/files\/timpanometro_horentek_espirio.png?v=1740058448"},{"product_id":"timpanometro-palmare-interacoustics-mt10-reflex-con-riflessi-ipsi","title":"INTERACOUSTICS MT10 Reflex handheld tympanometer (with IPSI reflexes)","description":"\u003cstrong\u003eThe MT10 automatic tympanometer is fast and easy to use and provides objective measurements that cannot be obtained with an otoscope alone.\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eRapid screening: \u003c\/strong\u003ein modern and busy practices, it is essential to perform fast and reliable tests. \u003cbr\u003e\nThe MT10 is built to meet these needs effectively, easily, and affordably.\u003cbr\u003e\n\u003cstrong\u003eFast and easy tympanograms:\u003c\/strong\u003e results can be obtained easily and quickly without the need for a patient response. \u003cbr\u003e\nOtitis media, the leading cause of temporary or permanent hearing impairment in children, can be easily and quickly detected with the MT10: this is a great advantage in the case of difficult-to-manage patients or young children. \u003cbr\u003e\nThe MT10 is also suitable for diagnostic use as tympanograms and reflexes are recorded in great detail. \u003cbr\u003e\nWith the new MT10, you can detect otitis media, a perforated eardrum, cholesteatoma, and clear neurological disorders. \u003cbr\u003e\nIt is also possible to check tympanostomy tubes and verify the results following medical treatments.\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eMain features:\u003c\/strong\u003e\u003cbr\u003e\n- From -400 to +200 daPa\u003cbr\u003e\n- Ipsilateral reflexes\u003cbr\u003e\n- Up to 30 patients in memory\u003cbr\u003e\n- Fast and reliable\u003cbr\u003e\n- Easy to transport: lightweight, handheld\u003cbr\u003e\n- 30 patients in memory: MT10 can store test results for up to 30 patients\u003cbr\u003e\n- Data upload for printing\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eIpsilateral Acoustic Reflexes:\u003c\/strong\u003e\u003cbr\u003e\nFour different reflex tests can be performed per ear using either a selection of fixed or automatic intensities. \u003cbr\u003e\nThe test is performed at the correct pressure level and the actual reflex characteristics are displayed on the screen to be read and interpreted by the operator.\u003cbr\u003e\n- 4 frequencies (500, 1000, 2000, 4000 Hz)\u003cbr\u003e\n- Single or multiple threshold search as a dB level\u003cbr\u003e\n- Automatic threshold search\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eTechnical specifications:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eTympanometry:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eInstrument type:\u003c\/strong\u003e screening tympanometer\u003cbr\u003e\n\u003cstrong\u003eTests performed:\u003c\/strong\u003e compliance peak level (in ml), peak pressure, gradient (in daPa), ear canal volume\u003cbr\u003e\n\u003cstrong\u003eProbe tone level:\u003c\/strong\u003e 226Hz (+\/-2)\u003cbr\u003e\n\u003cstrong\u003ePressure levels:\u003c\/strong\u003e from +200 daPa to -400 daPa\u003cbr\u003e\n\u003cstrong\u003eEar volume measurement range:\u003c\/strong\u003e from 0.2ml to 5ml (+\/-0.1ml)\u003cbr\u003e\n\u003cstrong\u003ePressure limits (safety shut-off):\u003c\/strong\u003e from +600 to -800 daPa\u003cbr\u003e\n\u003cstrong\u003eReflex measurement:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eMeasurement type:\u003c\/strong\u003e ipsilateral\u003cbr\u003e\n\u003cstrong\u003eReflex levels:\u003c\/strong\u003e 500 Hz, 1 kHz, 4 kHz\u003cbr\u003e\n\u003cstrong\u003eFour reflex levels:\u003c\/strong\u003e 100 dB with 5 dB or 10 dB steps\u003cbr\u003e\n\u003cstrong\u003eReflex analysis:\u003c\/strong\u003e 95 dB, 90 dB, or 85 dB with 5 dB steps\u003cbr\u003e\n\u003cstrong\u003eReflex analysis:\u003c\/strong\u003e pass\/refer of the reflex tested at each level\u003cbr\u003e\n\u003cstrong\u003eStored examples:\u003c\/strong\u003e 30 per tympanogram\u003cbr\u003e\n\u003cstrong\u003eTime and date:\u003c\/strong\u003e applied to all stored data and the last calibration date.\u003cbr\u003e\n\u003cstrong\u003eInternal backup power:\u003c\/strong\u003e \u0026gt; 30 days without main batteries\u003cbr\u003e\n\u003cstrong\u003ePrinted information:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eData collection:\u003c\/strong\u003e patient initials, tympanogram and reflex graphs, analysis per left and\/or right ear, time and date of measurement, ear analyzed, whether the data has been printed and\/or sent to the PC, parameters used for analysis\u003cbr\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eBatteries:\u003c\/strong\u003e 4 AA alkaline batteries or 4 rechargeable NiMH batteries, which must have a capacity greater than 2.3Ah.\u003cbr\u003e\n\u003cstrong\u003eBattery life:\u003c\/strong\u003e approximately 400 tests (AA alkaline batteries)\u003cbr\u003e\n\u003cstrong\u003eCompatible printers:\u003c\/strong\u003e Martel MCP8830 or Sanibel MPTII\u003cbr\u003e\n\u003cstrong\u003ePrinted info:\u003c\/strong\u003e Space for patient and physician details, tympanogram analysis parameters, tympanogram, reflex analysis parameters, reflex graph, device serial number, date of last and next calibration\u003cbr\u003e\n\u003cstrong\u003eDisplay:\u003c\/strong\u003e 128x64 pixels\u003cbr\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e (L) 190 mm x (D) 80 mm x (H) 40 mm excluding probe (H 225 mm including probe)\u003cbr\u003e\n\u003cstrong\u003eWeight (without batteries):\u003c\/strong\u003e 285g (380g with batteries)\u003cbr\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e IEC 60601-1\u003cbr\u003e\n\u003cstrong\u003eEMC:\u003c\/strong\u003e IEC 60601-1-2\u003cbr\u003e\n\u003cstrong\u003eImpedance:\u003c\/strong\u003e IEC 60645-5, Type 2 Tympanometer\u003cbr\u003e\n\u003cstrong\u003eCE mark\u003c\/strong\u003e\u003cbr\u003e\n\u003cbr\u003e\n\u003cstrong\u003eIncluded:\u003c\/strong\u003e\u003cbr\u003e\n1 MT10 unit with handle\u003cbr\u003e\n1 Set of disposable tips (mixed sizes)\u003cbr\u003e\n4 1.5V batteries\u003cbr\u003e\n1 User manual\u003cbr\u003e\n1 Warranty\u003cbr\u003e","brand":"Interacoustics","offers":[{"title":"Default Title","offer_id":49817555140944,"sku":"DG0007671","price":2835.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0866\/3996\/8592\/files\/DG0007671_249cd22e-d1ab-420c-b0fe-cc4a200addc9.jpg?v=1740088137"}],"url":"https:\/\/www.cfs.it\/en\/collections\/diagnostica-audiologia-e-orl-timpanometri.oembed","provider":"CFS Prodotti Medicali s.r.l.","version":"1.0","type":"link"}